Acuity Brands HEALTHCARE LIGHTING RK3HPL Podręcznik - Strona 5
Przeglądaj online lub pobierz pdf Podręcznik dla Sprzęt oświetleniowy Acuity Brands HEALTHCARE LIGHTING RK3HPL. Acuity Brands HEALTHCARE LIGHTING RK3HPL 8 stron.
912-00300-004
1
Remove lens by gently pressing on the center of
the lens and inserting a screwdriver between the
lens and the housing.
3
Replace with new light engine by gently pushing
in wires into light engine connecter, then replacing
#6-32 fasteners. Test the fixture prior to
reinstalling the lens.
**IMPORTANT**
- RK1HPL Kit: LED Board screw torque 11 in/lb +/- 4 in/lb
- All other fasteners 17 in/lb +/- 4 in/lb
- RK1HPL Kit will come with replacement fasteners and jumper wires. New or existing fasteners and jumper wires
may be used during the repair process.
© 2021 Acuity Brands Lighting, Inc. All Rights Reserved. "Healthcare Lighting" is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty
applies. Complete warranty terms located at
www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
8/2021
One Lithonia Way, Conyers, GA 30012
2
Disconnect damaged light engine by gently
pressing down on the channel connectors while
pulling outward on wire. Remove the #6-32
fasteners securing the light engine to the reflector.
•
Tel: 800-705-SERV (7378)
• Website: https://acuitybrands.com/
HPL REPAIR KIT INSTRUCTIONS
5