About Cisco 1100 Terminal Gateway Routers
Table 2: LED Indicators for Cisco Cisco 1100 Terminal Gateway Router
Port
System LEDs
LAN Port LEDs
WAN Port LEDs
ASYNC Port LEDs
Power Supply
The product power specifications are as follows:
• AC input voltage: 100 to 240 VAC, 1.6 A, 50-60 Hz
• DC input voltage: 48 to 60 VDC, 4.2 amp
• External power supply option - 100-240 VAC, 50 - 60 Hz
• HVDC power supply – 240 VDC, 0.9 A
Slots and Interfaces
About Slots, Subslots, and Port Numbering
The following figure shows slots and subslots numbering for C1100TG-1N32A:
LED Color
Description
Green and Amber
Off—Systempower off
Steady Green - System
operates normally.
Blinking Green —
BIOS/Rommon is
booting.
Steady Amber — Thermal
trip.
Blinking Amber – Alarm,
Secure boot failure.
Green
Off— No link
Steady On— Link
Blink - TXD/RXD Data
Green and Amber
Green - Indicates SFP
module detected
Amber - Indicates SFP is
not detected or at fault
Green
link established
Hardware Installation Guide for the Cisco 1100 Terminal Gateway
Power Supply
Control Source
Bezel side. All models.
Bezel Side
Bezel Side
Rear side