3. MAINTENANCE
3.1 Cleaning
3.1.1
Make sure the unit is de-energized.
3.1.2
Wipe off exterior dirt and debris using a soft, clean cloth.
CAUTION
DO NOT USE ABRASIVE CLEANSERS ON OPTICAL SURFACES.
THEIR USE MAY RESULT IN THE LOSS OF OPTICAL EFFICIENCY.
3.2 Electrical Component Replacement
3.2.1
Make sure the unit is de-energized. Open housing door by
unscrewing latch and swinging open.
3.2.2
To replace photocontrol. (If provided) Make sure the unit is
de-energized. Twist counterclockwise and remove. Replace with
equivalent photocontrol. See Figure 1. If no other components are to
be replaced go to Section 3.2.6.
3.2.3
To replace driver. Make sure the unit is de-energized.
Disconnect input and output via quick disconnects and remove (2)
mounting screws. Replace with Holophane approved driver. See
Figure 8. If no other components are to be replaced go to Section
3.2.6.
Figure 8
3.2.4
To remove surge protector, disconnect quick disconnect plug
coming from terminal and quick disconnect going to optical
compartment. Remove (2) screws connecting driver bracket to door;
retain screws for re-installation. Disconnect surge protector via quick
disconnect.
3.2.4.1
For wire tie fastened units, cut wire tie to remove surge
protector. Replace with Holophane approved device. Secure to
driver bracket with wire tie. Reconnect quick disconnect. See Figure
8.
3.2.4.2
For screw fastened units, remove surge protector by
removing screw. Retain for re-installation. Replace with Holophane
approved device. Secure to driver bracket with screw torqued to 15
in-lb. Reconnect quick disconnect. See Figure 8.
Replace driver bracket and screws. Reconnect quick disconnect plug
from terminal block and quick disconnect plug going to optical
compartment. If no other components are to be replaced go to Section
3.2.6.
3.2.5
Bundle and secure the wiring in a manner similar to the way it
was originally secured to avoid pinching of wires when re-installing the
module into the housing.
3.2.6
Close the housing by carefully swinging door shut while
ensuring no leads are pinched. Engage and secure the latch.
3.2.7
Energize the unit and check for proper operation.
4. AO and P7/PR7/P7E/PR7E options
When P7, PR7, P7E or PR7E options are ordered with AO, driver
dimming leads are wired to the AO module. The 7-pin receptacle
dimming leads (Pins 4 & 5) are routed to the driver tray but are capped
off enabling a transfer of driver dimming wires from the AO module to
the 7-pin receptacle. These leads must be disconnected from the AO
module and reconnected to the P7 or PR7 receptacle (Pins 4 and 5)
for an adaptive control to function when installed in the
P7/PR7/P7E/PR7E receptacle.
5. LIMITED WARRANTY AND
LIMITATION OF LIABILITY
The Holophane limited warranty and limitation of liability is published in
the "Terms and Conditions" section of the current Holophane buyer's
guide and is available from your local Holophane sales representative.
GR2661
IM-431-A