Cisco IC3000 Dokumentacja produktu - Strona 3
Przeglądaj online lub pobierz pdf Dokumentacja produktu dla Gateway Cisco IC3000. Cisco IC3000 12 stron. Industrial compute gateway
Również dla Cisco IC3000: Instrukcja instalacji sprzętu (37 strony)
Warning:
Read the installation instructions before connecting the system to the power source. Statement 1004
Warning:
Exposure to some chemicals could degrade the sealing properties of materials used in the sealed relay
device. Statement 381
Warning:
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: 5A. Statement 1005
Warning:
This unit is intended for installation in restricted access areas. A restricted access area can be accessed
only through the use of a special tool, lock and key, or other means of security. Statement 1017
Warning:
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning:
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning:
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of 140°F (60°C). Statement 1047
Warning:
Installation of the equipment must comply with local and national electric codes. Statement 1074
Warning:
Explosion Hazard—The area must be known to be nonhazardous before installing, servicing, or replacing
the unit. Statement 1082
Warning:
Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature outside
the enclosure. Statement 1067
Warning:
Avoid using or servicing any equipment that has outdoor connections during an electrical storm. There
may be a risk of electric shock from lightning. Statement 1088
Caution:
Airflow around the device must be unrestricted. To prevent the device from overheating, ensure that a minimum
of 1 inch of space exists around the device.
Contact your Cisco Technical Assistance Centre (TAC) if tighter spacings are required.
Caution:
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D, or only nonhazardous locations.
Caution:
The equipment shall only be used in an area of not more than pollution degree 2 as defined by EN 60664-1. In
addition, the equipment shall be installed in a certified enclosure that provides a degree of protection not less than IP 54
in accordance with EN 60079-15.
Note:
This equipment is rated as follows:
- DC Input Voltage: Maximum Operating Range: 9.6VDC to 60VDC; Nominal: 12VDC to 48VDC
Note:
The maximum ambient operating temperature range is -40 to 140°F (-40 to 60°C).
3