4.3 Timers setting
Push Buttons functions
Button
SET1---ON
OPN
Open cycle time set
CLS
Close cycle time set
PED
PED cycle time set
STP
Sync motor time set
OSC
Auto close time set
PEB
PE close time set
4.3.1 Set1 time settings
Turn SET1 on, red and green LED flashes a little fast alternatively.
Open cycle time
Push and hold on OPN for the full open run time setting
Close cycle time
Push and hold on CLS for the full close run time setting
Pedestrian running time
Push and hold on PED for the pedestrian open run time setting
Sync delay time(Motor2 delay time)
Push and hold on STP for the sync delay time setting.
Auto close time set
Push and hold on OSC for the auto close time setting.
PE close time set
Push and hold on PEB for the PE close time setting.
4.3.2 SET2 time setting
Turn SET1 off and SET2 on
Warn time set
Push and hold on OPN for Warning time setting.
Lock pulse time set
Push and hold on CLS for the lock pulse time setting
LGT time
Push and hold on PED for the PE trig close time setting
Motor Stop time
Push and hold on STP for the motor stop time setting
.
Two-T1 time1 (spare for late use)
Push and hold on OSC for the Two-T1 time setting
Two-T2 time2 (spare for late use
Push and hold on PEB for the Two-T2 time setting.
Turn SET2 OFF. The gate controller will back to working mode.
Digiway Pty Ltd
CONTROL INPUIT AND BUTTON
SET2 --- ON
Warning time set
Lock time set
LGT time set
Motor stop time set
Two T1 --spare
Two T2 -- Spare
8
Set1 and Set2 both off---Running
Open gate
Close gate
Partial open gate
Stop gate
Open-Stop-Close gate
PE. Input (simulated)