DIGIWAY PTY SL2000 Instrukcja obsługi - Strona 9
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Otwieracz drzwi garażowych DIGIWAY PTY SL2000. DIGIWAY PTY SL2000 11 stron. Sliding gate motor
Factory setting
Timer
F/Setting
Open Cycle Time
60sec.
Close Cycle Time
60sec.
Ped Cycle Time
10sec.
Sync Delay Time
2sec.
Auto Close Time
30sec.
PE Auto close Time
2sec.
Warning time
3sec
Lock Pulse Time
1sec.
Light Time
60sec
Motor Stop Time
0.5sec
Two-T1 Time(spare)
60sec
Two-T2 Time(spare)
60sec
To restore factory setting, turn power off and set SET1 on, push and hold CLS button, then power
on. While hold CLS button, set SET1 off and then release the CLS button. Now controller restored
factory setting from memory.
5. Light output
With the additional module, which plugs into the control board, the control board will control
light, which will illuminate the driveway etc. The light will automatically turn off after preset time
(customer programmable). If DIP4 is set to ON, the M2 output will change to light output.
6. Audio warn output
On Board buzzer can give warn for diagnose. Additional buzzer or relay module, which plugs
into the control board, the control board give out audio warning signals before gate moves
If PB beam is blocked or Stop input is not shorted, four short bee will be heard
Digiway Pty Ltd
CONTROL INPUIT AND BUTTON
Step
Setting Method
0.1sec
SET1 on + OPN Button
0.1sec.
SET1 on + CLS Button
0.1sec.
SET1 on + PED Button
0.1sec.
SET1 on + STP Button
0.1sec.
SET1 on + OSC Button
0.1sec.
SET1 on + PEB Button
0.1sec
SET2 on + OPN Button
0.1sec
SET2 on + CLS Button
0.1sec
SET2 on + PED Button
0.1sec
SET2 on + PED Button
0.1sec
DIP2 on + OSC Button
0.1sec
DIP2 on + PEB Button
9
Range
0-6550sec.
0-6550sec.
0-6550sec.
0-25sec.
0-6550sec.
0-25sec.
0-25sec
0-25sec
0-6550sec
0-25sec
0-6500sec
0-6500sec