Acuity Brands Lithonia Lighting Quantum ELM6 LED Instrukcja instalacji - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Oprawa oświetleniowa Acuity Brands Lithonia Lighting Quantum ELM6 LED. Acuity Brands Lithonia Lighting Quantum ELM6 LED 8 stron. Emergency lighting units
page 4
Battery replacement:
Disconnect battery connector. Release hook-and-loop strap and
remove battery. Disconnect leads and connect to new battery. Install
new battery in orientation shown below and secure
Reconnect the battery connector.
Charger board replacement:
Flex the snap at each end of the charger board, and pull
board straight out of the housing. Re-connect all leads to the new
charger board. Slide the new charger board into place, making sure it
is secured by both snaps
.
Federal Communications Commission (FCC) Requirements:
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
MAINTENANCE
the
strap.
Snaps
the charger
Lamp Replacement:
Remove lamp bezel
as shown below
from lamp assembly. Gently bend the snap at each side of the collar
outward to release the lamp assembly. Replace lamp assembly firmly
under the snaps on the collar, making sure the lamp wires are not
pinched. Reattach the lamp connector and replace the bezel.
To remove lamp bezel, carefully p
(do not use tool)
Bezel
To remove lamp assembly, release snaps
Important Battery Information:
Batteries are perishable items. For best results, it is recommended
that the batteries receive an initial charge within the first six months of
the manufacture date of the fixture. The manufacture date can be
found on the outside of the unit packaging and on the UL label as part
of the Date Code / Series. The first two digits in the date code
represent the year and the second two digits represent the month. In
many cases, batteries beyond the initial charge recommendation time
frame will recover if fully charged soon after installation. If such a
battery does not recover after a full initial charge, it should be
replaced.
EMERGENCY LIGHTING SYSTEMS
TEL: 800-334-8694 www.lithonia.com
. Carefully unplug connector
ry here at each side
Collar
Connector
Part # EMCSA00865
Rev B (1/12/16)