DigiWeight DWP-11KR Podręcznik użytkownika - Strona 8

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Wagi DigiWeight DWP-11KR. DigiWeight DWP-11KR 10 stron. Floor / pallet scale

the high-limit and the low-limit are set as same value, the indicator will set alarm for one key point. If
the high-limit is set higher than the low-limit, the indicator will set alarm for a weighing range.
To set check-weighing parameters: when the indicator is off, turn it on and press [ZERO] key when
the indicator is still warming up. You will see "F1 CLK" on the screen. Press [TARE] key 3 times
and the screen will show "F4
CHK". Press [FUN] key to enter beep mode setting:
Beep 1: No beep. When the weight is higher than the high-limit, HI will be on. When the weight is
lower than the low-limit, LO will be on. Otherwise both HI and LO will be on.
Beep 2: Beep when the weight falls into the weight range.
Beep 3: Beep when the weight falls out of the weight range.
Press [TARE] key to select desired mode then press [FUN] key to set High-limit:
Now there are 6 zeros on the screen. Press [ZERO] key to move the editable digit (blinking) and
press [TARE] to change the value. When you are done, press [FUN] to set Low-limit. When you are
done, press [FUN] to confirm. The screen will go back to "F4 CHK"
To disable the check-weighing function, press [UNIT] key to set both high-limit and low-limit to zero.
3.10 PRINTING (WHEN F3 KEY=2)
Set P 10 as "RS" (We will show to how to set P value later on.)
In the weighing mode, press [MOD] to print.
Chapter 4 Setting Parameters
To enter parameter setting: Turn on the indicator and press [ZERO] key when the indicator is still
warming up.
4.1 "F1 CLK" DATE AND TIME SETTING
Press [FUN] key to show the current time. If it is not correct, adjust it as following:
Press [ZERO] key to change hour (the hour is blinking). Press [TARE] to add up until it shows the
correct hour. Press [ZERO] to move to the minutes (the minutes are blinking). Press [TARE] to add
up until it shows the correct minute. Press [ZERO] to move to the seconds (the seconds are blinking).
Press [TARE] to add up until it shows the correct second.
Press [FUN] to confirm and move to date mode setting. There are 3 date showing modes:
"YY-MM-DD", "MM-DD-YY" and "DD-MM-YY". Press [TARE] key to switch between and press [FUN]
to confirm then move to date setting. Use the same way as timing setting to set the date. Press
[FUN] to confirm and exit. During the time or date setting, you may press [MOD] anytime to cancel
and exit. System will not save the changes. Press [TARE] to move to the next parameter.
4.2 "F2 SLP" SLEEP SETTING
Press [FUN] and press [TARE] to select the desired setting from the available modes as following:
SLP OF: The indicator will never enter sleep mode.
SLP 1: The indicator will enter sleep mode if it is idle for 1 minute.
Floor / Pallet Scale