Monitoring window layout
High-temperature warning
Error information: Shows a notification or warning/problem status using the
following icons.
Clean Air Filter Notice
*4
Replace Lamp
High-temperature warning
Replace Air Filter
No Air Filter
Low Air Flow
Air Flow Sensor Err.
Low air flow error
Air filter air flow sensor error
Other error
*1 When Temperature level display group view is set to On at Environment
setup in the Tool menu, an icon indicating the internal temperature of the
projector will be displayed on top of the projector icon. The default
setting is Off.
*2 Check the following items.
- Check that the projector's power is turned on.
- Check that the LAN cable is connected.
- Check that Network Monitoring is set to ON or Standby Mode is set to
Network ON in the projector's configuration menu.
*3 Check that the projector has been correctly connected to the network.
*4 You can display Replace lamp at any time preset at Environment setup in
the Tool menu.
Lamp Cover Open
Lamp Error
Lamp failure at power on
High internal temperature error
Internal Error
Fan error
Sensor error
Supply System Error (Ballast)
Auto Iris Error
• The projector information that is generated when a problem is
q
detected is stored until EMP Monitor is closed. EMP Monitor
displays will not be updated automatically even if the projector
status returns to normal. Click "Refresh" in the main window to
update the status.
• Detectable error information differs with the projector you are
using.
Selecting display items
You can select only the required items to be displayed in Detail list view.
Procedure
A
Select "Option" from the View menu.
The Option window will be displayed.