ECI CabLite ECO 3000K Instrukcja instalacji - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Oprawa oświetleniowa ECI CabLite ECO 3000K. ECI CabLite ECO 3000K 14 stron.

6.4 CabLite ECO with Dimming and Emergency Lighting Option

This option allows for brightness control and emergency lighting. Included with this option:
1 to 12 downlights
Emergency Light board (factory wired and mounted in gang box)
24VDC power supply (factory wired and mounted in gang box)
12 Volt Battery (Factory wired w/ + side disconnected)
Two 8' cables for connecting first downlights (factory wired and located in gang box)
One 4' cable for each additional downlight
Gang box and cover
Installation Manual
This option allows for brightness settings and emergency lighting (2 downlights). In addition, there is a
standby mode that will turn off all downlights when cab is not in use. This is achieved with a key switch
connected to the STBY input pins 9 & 10.

6.4.1 CabLite ECO Emergency Board Connections

Refer to Figure 3 - CabLite ECO Emergency Board
Pin 1 (IN +) is +24VDC input power (RED Wire)
Pin 2 (IN-) is -24VDC input (BLACK Wire)
Pin 3 (OUT+) is + output for general power (AC present) Downlight String (RED Wire)
Pin 4 (OUT-) is – output for general power downlight string (BLACK Wire)
Pin 5 & 6 is for external potentiometer (customer provided) for brightness adjustment
Pin 7 (EM+) is + output for EMERGENCY downlight string (2 downlights) (RED wire)
Pin 8 (EM-) is – output for EMERGENCY downlight string (2 downlights) (Black wire)
Pin 9 & 10 (STBY) – is for external key switch that turns all downlights off when pin 9 & 10 are
closed. When closed EMERGENCY downlights will light only if AC power is lost.
Pin 11 (BAT+) + side connection to battery
Pin 12 (BAT-) – side connection to battery
Pin 13 is FAULT relay common
Pin 14 is Normally Closed contact of fault relay: Contacts open (between Common pin 13) when
there is a Battery Fault
Pin 15 is the Normally open contact of the fault relay: Contacts close (between Common pin 13)
when there is a battery fault.
Cablite ECO Installation Manual Rev 4.0
Figure 2 - Dimmer Board
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com
P a g e