1. ADJUSTMENT PROCEDURE

Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
Use an isolation transformer when performing any
service on this chassis.
Before removing the anode cap, discharge electricity
because it contains high voltage.
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
When you exchange IC and Transistor for a heat sink,
apply the silicon grease on the contact section of the
heat sink. Before applying new silicon grease, remove all
the old silicon grease. (Old grease may cause damages
to the IC and Transistor).
Prepare the following measurement tools for electrical
adjustments.
1. Oscilloscope
2. Digital Voltmeter
3. Pattern Generator
On-Screen Display Adjustment
1. In the condition of NO indication on the screen.
Press the VOL. DOWN button on the set and the
Channel button (9) on the remote control for more than
2 seconds to appear the adjustment mode on the
screen as shown in Fig. 1-1.
35 H POSI OSD
36 V POSI OSD
37 H POSI TEXT
38 V POSI TEXT
39 H POSI 60
00 CUT OFF
9- EXT
2.
Use the Channel button (0-9) or Channel UP/DOWN
button on the remote control to select the options
shown in Fig. 1-2.
3.
Press the MENU button on the remote control to end
the adjustments.
NO.
FUNCTION
00
CUT OFF
01
RF AGC
02
AGC GAIN
03
R DRIVE
04
R CUTOFF
05
G DRIVE
06
G CUTOFF
07
B DRIVE
08
H POSI (50)
09
V POSI (50)
10
V POSI (60)
11
V SIZE (50)
12
V SIZE (60)
13
VCO COARSE
14
VCO FINE
15
VCO COARSE L1
16
VCO FINE L1
17
BRIGHT CENT
18
BRIGHT MAX
19
BRIGHT MIN

ELECTRICAL ADJUSTMENTS

120
57
119
57
34
VCO Status
-
MMM
Fig. 1-1
NO.
FUNCTION
20
TINT
21
SHARP
22
CONTRAST CENT
23
CONTRAST MAX
24
CONTRAST MIN
25
COLOR CENT
26
COLOR MAX
27
COLOR MIN
28
M R CUT OFF
29
M G CUT OFF
30
M B CUT OFF
31
CVBS OUT
32
APR THRESHOLD
33
BELL FILTER
34
BANDPASS
35
H POSI OSD
36
V POSI OSD
37
H POSI TEXT
38
V POSI TEXT
39
H POSI (60)
Fig. 1-2

2. BASIC ADJUSTMENTS

2-1: CONSTANT VOLTAGE
1.
Place the set with Aging Test for more than 5 minutes.
2.
Connect the digital voltmeter to TP501.
Set condition is AV MODE without signal.
3.
Adjust the VR501 until the DC voltage is 117 ± 1.0V.
4.
2-2: VCO
1.
Place the set with Aging Test for more than 10 minutes.
2.
Connect the oscillator (38.9MHz) to TP001.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (13) on the remote control to
select "VCO COARSE".
4.
Press the VOL. +/- button on the remote control until
the "OK" appear on the screen. If the "OK" is not
displayed, select the "+" side on the changed from "+"
to "-".
5.
Press the Page UP button once to set to "VCO FINE"
mode.
6.
Press the VOL. +/- button on the remote control to
select the 5 step down point from the upper limit on the
"OK".
(Example: In case of the "OK" range 30~41, select 36.)
2-3: VCO COASE L1, VCO FINE L1
1.
Place the set with Aging Test for more than 10 minutes.
2.
Connect the oscillator (33.95MHz) to TP001.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (15) on the remote control to
select "VCO COARSE L1".
4.
Press the VOL. +/- button on the remote control until the
"OK" appear on the screen. If the "OK" is not displayed,
select the "+" side on the changed from "-" to "+".
5.
Press the Page UP button once to set to "VCO FINE
L1" mode.
6.
Press the VOL. +/- button on the remote control to select
the 5 step down point from the upper limit on the "OK".
(Example: In case of the "OK" point 30~41, select 36.)
2-4: AGC VOLTAGE
1.
Place the set with Aging Test for more than 15 minutes.
Receive the UHF (63 ± 1dB).
2.
3.
Connect the digital voltmeter to pin 5 of CP101.
4.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (01) on the remote control to
select "RF AGC".
5.
Press the VOL. +/- button on the remote control until the
digital voltmeter is 2.6 ± 0.05V.
2-5: FOCUS
1.
Receive a 70dB monoscope pattern.
2.
Turn the Focus Volume fully counterclockwise once.
3.
Adjust the Focus Volume until picture is distinct.
2-6: CUT OFF
1.
Set condition is AV MODE without signal.
2.
Using the remote control, set the brightness and
contrast to normal position.
3.
Place the set with Aging Test for more than 15 minutes.
4.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (00) on the remote control to
select "CUT OFF".
5.
Adjust the Screen Volume until a dim raster is obtained.
D-1