Dimplex 6909590100 Instrukcja serwisowa - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Grzałka Dimplex 6909590100. Dimplex 6909590100 17 stron.

Dimplex 6909590100 Instrukcja serwisowa

PREPARATION FOR SERVICE

!
NOTE: All components are replaceable from the front of
the fireplace while the unit is mounted on the wall, with the
exception of replacement of the power cord.
!
NOTE: If the power cord needs replacing or if the unit
needs to be removed from the wall for any other reason
please begin service by following the "PREPARATION FOR
SERVICE" instructions, then move on to the section "IN-
STRUCTIONS FOR REMOVING FROM WALL".
Tools Required: Phillips head screwdriver
WARNING: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
CAUTION: If unit was operating prior to servicing allow
at least 10 minutes for lights and heating elements to cool
off to avoid accidental burning of skin.
1. Disconnect power source.
Unplug the fireplace from the outlet.
If unit has been hard wired for power or outlet is
not accessible from the front, turn the breaker off at
the electrical panel.
2. Remove the front glass assembly by removing the 2
screws (1 on the left and 1 on the right side). These
screws secure the front glass panel to the inside of the
fireplace. (Figure 4)
3. Lift the front glass assembly off of the 4 mounts located
between the outer and inner casing of the fireplace: 2
on the left and 2 on the right. (Figure 3) Carefully place
the glass assembly aside in a safe location.
4. Proceed to the instructions within this manual relating
to the repair being performed - see Table of Contents
for page number.
INSTRUCTIONS FOR REMOVING FROM
WALL
!
NOTE: Only required for replacement of the
power cord or removal from service.
WARNING: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
CAUTION: If unit was operating prior to servicing allow
at least 10 minutes for lights and heating elements to cool
off to avoid accidental burning of skin.
CAUTION: Follow "Preparation for Service" instructions
before proceeding.
Mounting - The fireplace may be mounted in one of 3 meth-
ods:

Surface Mount

Recess Mount - Partial In-Wall
Flush Mount (completely in the wall)
Identify the type of mounting and follow the appropriate
instructions in the following pages.
CAUTION: To prevent injury or damage, turn off the
breaker in your electrical panel prior to attempting to re-
Figure 3
Front glass
assembly
Mounts (4)
Hooks (4)
Figure 4
move this unit off the wall.
!
NOTE: If fireplace is hard wired directly to the electrical
panel, and there is not enough slack in the wires within the
wall to reach your work area, remove the electrical junction
box cover located on the bottom right by removing the 2
screws on the front of the cover. Lift the cover off and set
aside. Disconnect the 3 wire connectors connected to the
power source, taking note of their original configuration
• Line: Red wire from unit to the line wire power source
• Neutral: Thin white wire and thick blue wire to neutral
wire from power source
• Thin black wire and thick white wire are left connect-
ed and not changed.
Surface Mount
(Figure 6)
Tools Required: Phillips head screwdriver
CAUTION: Follow "Preparation for Service" instructions
before proceeding.
1. Remove the decorative acrylic ember-bed pieces from
the media tray, which lies along the bottom of the interi-
or Partially Reflective Glass. A medium sized container
such as a bucket or a box will be needed to keep the
acrylic ember-bed pieces together.
2. On the bottom of the unit remove the securing screw
from the L-bracket. (Figure 5)
3. Lift the unit up and off of the wall.
4. Carefully lay the unit down on a solid flat surface with
the front of the unit facing up.
Front tray
Tab
7