CONSTRUCTIONAL HEARTH
300
125mm THICK MINIMUM
Table 3 Position of Hearth & Appliance In Relation to walls
Hearth distance from wall 'X'
0mm
0mm
0 - 150mm
+150mm
8
Seal with fire
proof lagging
150
NON COMBUSTIBLE
Appliance distance from wall
0 - 50mm
51 - 300mm
+150mm
+300mm
150 Max
45°
Max
5
7
H
See Table 3
T
X
MIN
125mm
Wall Dimensions
Min Wall Thickness 'T'
200mm
75mm
75mm
No Minimum Requirement
9
Seal gap with
fire-proof lagging
Solid, non-combustible
material e.g. masonary
or concrete
T
X
MIN
150mm
Min Wall height 'H'
Height of appliance +300mm
or 1200mm from hearth
(whichever is greater)
150 max
150 max