Aeon Labs AEOEZW062 Skrócona instrukcja obsługi - Strona 9
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Kontroler Aeon Labs AEOEZW062. Aeon Labs AEOEZW062 12 stron. Garage door controller
Select an alarm sound, there are 4 alarm sounds in the flash memory card can
256 — 356
be selected.
65535 —
Configure the volume of alarm sound, there are 10 levels can be set.
65545
16777215
Disable the alarm mode.
16777216
Enable the alarm mode.
Alarm Mode Closed Position (Parameter Number 40, Parameter Size 4) Configure the alarm
mode when the garage door is in closed position. Value1: configure the frequency of blinking
for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1
and the max frequency is level 10. Default is level 2. Value2: configure the alarm sound
(there are 4 types sound saved in EEPROM and user also can update it). Default is type 4.
Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level
and the max volume is 10 levels). Default is set to 8. Value4=0, disable the alarm prompt.
Value4=1, enable the alarm prompt.
Value
Configure the flash frequency of the alarm LED, there are 10 levels can be
1 — 10
set.
Select an alarm sound, there are 4 alarm sounds in the flash memory card can
256 — 356
be selected.
65535 —
Configure the volume of alarm sound, there are 10 levels can be set.
65545
16777215
Disable the alarm mode.
16777216
Enable the alarm mode.
Tamper Switch State (Parameter Number 41, Parameter Size 1) Configuration report for the
tamper switch State.
Value
0
The Sensor is installed on the garage door. (Default)
15
The Sensor is removed from the garage door.
Battery State of Sensor (Parameter Number 42, Parameter Size 1) Configuration report for the
battery state of Sensor.
Value
Description
0
Battery is in normal state. (Default)
15
Battery is in low battery state.
Ringtone (Parameter Number 43, Parameter Size 1) Start playing or Stop playing the ringtone.
Value
255
stop playing ringtone
1 — 100 Start playing the ringtone that you selected.
Ringtone Volume (Parameter Number 44, Parameter Size 1) Test the volume of the current
ringtone.
Value
1 — 10 There are 10 volume levels can be set for testing.
Temperature (Parameter Number 45, Parameter Size 2) Get the environment temperature: The
temperature value contains one decimal point. E.g. If the report value=252(0x00FC), the
temperature is 25.2℃. Rang is 0 to 500 (0 to 50.0℃).
Value Description
Description
Description
Description
Description