Pioneer AVX-7000 Instrukcja serwisowa - Strona 27
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Odbiornik samochodowy Pioneer AVX-7000. Pioneer AVX-7000 32 stron. 7 inch wide av system display
Również dla Pioneer AVX-7000: Podręcznik (24 strony), Instrukcja serwisowa (16 strony)
7.3 MECHANISM DESCRIPTIONS
- Outlines of the hardwares
Drive motors
Discharge (position) motor
Angle raising (angle) motor
Sensors
Angle detection rotary encoder
End of discharge detecting switch ("L" when
detection is made)
Angle 0-degree detecting switch
End of storage detecting switch ("L" when
detection is made)
- Outline of the operation
1. The motor will run during the time while the ANGLE +/- key is being pressed and held.)
2. Two motors of the longitudinal direction drive motor and angle control motor work to drive the movements.
3. Analog potential being generated from the angle encoder will be detected to find out the angular movements and
positions. Meanwhile, horizontal intermediate position detections will not be made.
4. When the operation is started after resetting, the system goes into the storage stage once, before proceeding to the
discharging movement to be started up.
5. Angular adjustments can be performed by use of the angle adjusting keys.
6. By pressing the "OPEN" key once again (or by ACC OFF (While the automatic open-close setting is being turned
"ON")), the system starts storage movement.
- Electric conditions
Sensor signals
Encoder
ANGLEIN: Angle sensing analog sensor
Sensor signals
(PUSH)
LIFT SW: End of discharge detecting sensor ("L"
when detection is made)
PULL SW: End of storage detecting sensor ("L"
when detection is made)
Control signals
MTRPW : Motor power control ("H" when
turned "ON")
MTR1
: Angle motor control signal ("H" when
turned "ON")
MTR2
: Position motor control signal ("H"
when turned "ON")
MTRS
: Motor speed control ("L" for high
speed and "H" for low speed)
MTRSEL : Motor rotation direction control
(Horizontal IN: H/OUT:
(Angled UP: H/DOWN: L
Motor terminal voltage
High speed mode: VMH = 7.0V
Low speed mode: VML = 6.2V
AVX-7000