DINA DN3PD1 Oryginalna instrukcja obsługi - Strona 14

Przeglądaj online lub pobierz pdf Oryginalna instrukcja obsługi dla Urządzenia przemysłowe DINA DN3PD1. DINA DN3PD1 20 stron. Speed monitoring for one and three phases motors without sensor system
Również dla DINA DN3PD1: Tymczasowa instrukcja obsługi (8 strony)

DINA DN3PD1 Oryginalna instrukcja obsługi
DN3PD1
Parameterization of the switching thresholds

Configuration of the switching threshold and acknowledgement

The current settings can be checked by briefly pressing the SET button. The LEDs show the parameters binary
coded in five steps (Level). Two levels each determine V-LIMIT 1 and V-LIMIT 2 (see frequency table), the fifth level
indicates the type of acknowledgment.
The permanent pressing of the SET button starts the parameterization mode and the levels can be run through.
Releasing the button allows you to change this level parameter. The configuration can be adjusted by a short
touch of the button. The new setting is saved again by pressing the button permanently.
Each level can be recognized by its flashing rhythm or the LED color.
Level
1.1: column
SET
b8
b4
b2
b1
Adjusting by briefly pressing the SET button
 Press SET button for >2s until all LED flash green.
 Adjust V-LIMIT 1, Level 1.1 binary coded by short key press (column of the table 7-1)
 Keep the SET button pressed: The value is saved and displayed as continuous light.
 Keep the SET button pressed until the blinking rhythm of all LEDs changes.
 Adjust V-LIMIT 1, Level 1.2 binary coded by short key press (row of the table 7-1).
 Keep the SET button pressed: The value is saved and displayed as continuous light.
 Keep the SET button pressed until the color of all LEDs changes.
 Adjust V-LIMIT 2, Level 1.1 binary coded by short key press (column of the table 7-1)
 Keep the SET button pressed: The value is saved and displayed as continuous light.
 Keep the SET button pressed until the blinking rhythm of all LEDs changes.
 Adjust V-LIMIT 2, Level 1.2 binary coded by short key press (row of the table 7-1).
 Keep the SET button pressed. The value is saved and displayed as continuous light.
 Keep the SET button pressed until the LED flash in pairs.
 Adjust the acknowledgement*) by short key press
 Keep the SET button pressed: The value is saved and displayed as continuous light.
 Release the button. The configuration is completed. The unit is ready for operation, if the OK LED shows
green.
The set thresholds must be validated as follows:
Checking the set parameters in the display mode (short pressing of the SET key) and verification of
the correct safety functions by checking the shutdown speeds, e.g. by comparison with the speed dis-
played on the frequency converter or use of other suitable speed measuring equipment.
14
V-LIMIT 1
1.2: row
*) Adjust the acknowledgement
b8
b4
b2
b1
manual
V-LIMIT 2
2.1: column
2.2: row
Save: press SET button
b8
b4
b2
b1
-
SET
automatic
Acknowledgement
autom./manual
1s
>