(EN 60079-10 1)
orking areas
  
  
  T
  i iT
i iT
  i   
  iT   
t
emPeratUre and PressUre resistance
Variant
Temperature t
(Performance)
CLS 23N 10
-25°C ... +105°C
CLS 23E 10
-25°C ... +120°C
CLS 23NT 10
-30°C ... +150°C
CLS 23N 11
-10°C ... +105°C
CLS 23E 11
-10°C ... +105°C
CLS 23N 12
-25°C ... +105°C
CLS 23E 12
-25°C ... +120°C
CLS 23NT 12
-30°C ... +150°C
CLS 23N 20
-25°C ... +105°C
CLS 23E 20
-25°C ... +120°C
CLS 23NT 20
-30°C ... +150°C
CLS 23N 21
-25°C ... +105°C
CLS 23E 21
-25°C ... +120°C
CLS 23NT 21
-30°C ... +150°C
CLS 23N 30
-25°C ... +105°C
CLS 23E 30
-25°C ... +120°C
CLS 23NT 30
-30°C ... +150°C
* Valid for top mounting (in vertical position)
 Dinel
CLS 23
erformance for noneplosive areas
tended temperature performance for noneplosive areas
igh temperature performance for noneplosive areas
erformance for eplosive areas iThigh temperature
b with intrinsically safe supply units electrode part one  housing one 
erformance for eplosive areas
supply units whole sensor one 
igh temperature performance for eplosive areas
with intrinsically safe supply units electrode part one  housing one .
variants N, E, NT
Temperature t
Temperature t
p
m
-25°C ... +105°C
-20°C ... +80°C
-25°C ... +120°C
-25°C ... +105°C
-30°C ... +150°C
-20°C ... +80°C
-10°C ... +105°C
-10°C ... +80°C
-10°C ... +105°C
-10°C ... +105°C
-25°C ... +105°C
-20°C ... +80°C
-25°C ... +120°C
-25°C ... +105°C
-30°C ... +150°C
-20°C ... +80°C
-30°C ... +150°C * -20°C ... +80°C
-30°C ... +150°C * -25°C ... +105°C
-30°C ... +150°C
-20°C ... +80°C
-30°C ... +150°C * -20°C ... +80°C
-30°C ... +150°C * -25°C ... +105°C
-30°C ... +150°C
-20°C ... +80°C
-30°C ... +150°C * -20°C ... +80°C
-30°C ... +150°C * -25°C ... +105°C
-30°C ... +150°C
-20°C ... +80°C
    ia  T a with intrinsically safe
    ia  T ab
Max. operating pressure for temperature t
a
to 30°C
to 85°C
8 MPa
6 MPa
8 MPa
6 MPa
8 MPa
6 MPa
7 MPa
5 MPa
7 MPa
5 MPa
8 MPa
6 MPa
8 MPa
6 MPa
8 MPa
6 MPa
3 MPa
2,5 MPa
3 MPa
2,5 MPa
3 MPa
2,5 MPa
3 MPa
2,5 MPa
3 MPa
2,5 MPa
3 MPa
2,5 MPa
8 MPa
6 MPa
8 MPa
6 MPa
8 MPa
6 MPa
    ia  T a
p
to 105°C
to 130°C
do 150°C
5 MPa
5 MPa
5 MPa
4 MPa
3 MPa
4 MPa
4 MPa
5 MPa
5 MPa
5 MPa
4 MPa
3 MPa
2 MPa
2 MPa
2 MPa
1,5 MPa
1 MPa
2 MPa
2 MPa
2 MPa
1,5 MPa
1 MPa
5 MPa
5 MPa
5 MPa
4 MPa
3 MPa
17