Ariston AURES MULTI Instrukcja instalacji i obsługi - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Podgrzewacz wody Ariston AURES MULTI. Ariston AURES MULTI 13 stron.
Table 1: Recommended cable
Power
AURES M 9.5 240V EU
• Operating water pressure 50-800 kPa (0.5-8 bar) • Water pressure operating power switch
• Standard 1/2"Ø compression inlet connection • Top-Left and Optional Top-right cable entry • Bottom-right water entry
UNIT DIMENSIONS: HEIGHT 220mm WIDTH 304mm DEPTH 110mm
* Recommended power cable size: 6mm
Water Outlet
This product conforms to Directive WEEE 2012/19/EU.
The symbol of the crossed waste paper basket on the ap pliance indicates that at the end of its working
life the pro duct should be disposed of separately from normal domestic household rubbish, it must be
disposed of at a waste dispo sal center with dedicated facilities for electric and electronic appliances or
returned to the retailer when a new replace ment product is purchased. The user is responsible for the disposal of
the product at the end of its life at an appropriate waste disposal center. The waste disposal center (which using
special treatment and recycling processes effectively dismantles and disposes of the appliance) helps to protect
the environment by recy cling the material from which the product is made. For further information about waste
disposal systems visit your local waste disposal center or the retailer from which the product was purchased.
kW Loaded
220V
230V
240V
--
--
9.5
/10mm
(in the UK 10mm
2
2
Recommended
Heating setting
4.7+4.8 kW
H05VV-F 3x6mm² *
is a requirement where it runs longer than 10 metres).
2
7
Recommended
Cable
Fuse Rating
40A
Power Knob
Power LED
Water Inlet
Pressure Relief Valve
Filter
EN