Aeotec MULTISENSOR 6 Podręcznik - Strona 8
Przeglądaj online lub pobierz pdf Podręcznik dla Akcesoria Aeotec MULTISENSOR 6. Aeotec MULTISENSOR 6 10 stron. Z-wave water and flood sensor
Również dla Aeotec MULTISENSOR 6: Podręcznik użytkownika (13 strony), Podręcznik (3 strony), Podręcznik użytkownika (8 strony), Podręcznik użytkownika (13 strony)
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 101: To set what unsolicited report would be sent to the Lifeline group.
To set what unsolicited report would be sent to the Lifeline group.
Size: 1 Byte, Default Value: 3
Setting
0
1
2
3
Parameter 111: To set the interval time of sending reports in Report group 1
To set the interval time of sending reports in Report group 1.Note:1. The unit of interval time is second if USB power.2. If battery power, the minimum interval time
is equal to Wake Up interval set by the Wake Up CC.
Size: 4 Byte, Default Value: 3600
Setting
5 - 2678400
Parameter 135: To set which sensor report can be sent when the water leak event is triggered and if the receiving
device is a non-multichannel device.
To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device.
Size: 1 Byte, Default Value: 1
Setting
0
1
2
3
Parameter 136: When the parameter 135 (0x87) is set to 2 or 3, it can get the sensor probes status through this
configuration value.
When the parameter 135 (0x87) is set to 2 or 3, it can get the sensor probes status through this configuration value.Note: This parameter is a Get- only parameter.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
Parameter 201: Temperature sensor calibration
Temperature sensor calibration.Note:1. High byte is the calibration value. Low byte is the unit (0 (0x00)=Celsius, 1 (0x01)=Fahrenheit)2. The calibration value (high
byte) contains one decimal point. E.g. if the value is set to 20 (0x1400), the calibration value is 2.0 °C (EU/AU version) or if the value is set to 20 (0x1401), the
calibration value is 2.0 °F(US version) 3. The calibration value (high byte) = standard value - measure value.E.g. If measure value =25.3°C and the standard value
= 23.2°C, so the calibration value= 23.2°C - 25.3°C= -2.1°C (0xEB).If the measure value =30.1°C and the standard value = 33.2°C, so the calibration value=
33.2°C - 30.1°C=3.1°C (0x1F).
Size: 2 Byte, Default Value: 1
Setting
-128 - 127
Parameter 252: Enable/disable all configuration parameters to be locked
Enable/disable all configuration parameters to be locked.
Size: 1 Byte, Default Value: 0
Description
report the USB power level.
report the CR123A battery level.
Description
Send Nothing
Battery Report is enabled.
Multilevel sensor report for temperature is enabled.
Battery Report and Multilevel sensor report for temperature are enabled.
Description
Available rang is 5 to 2678400 seconds.
Description
Send nothing
Send notification report to association group 1.
Send configuration 136 (0x88) report to association group 2.
Send notification report to association group 1 and Send configuration 136 (0x88) report to association group 2.
Description
absence of water is triggered by probe 1.
presence of water is triggered by probe 1.
presence of water is triggered by probe 2.
Description
Available rang is -12.8°C to 12.7°C.