Green = Great Health
Manually Factory Reset TriSensor.
This method is not fully advised unless your gateway has failed, and you do not yet have another gateway to perform a
general unpair on TriSensor.
1. Press and hold TriSensor Action button
2. Wait until the RGB LED turns from:
- Red
- Orange
- Cyan
- Red LED flashes 5 times which will indicate a factory reset.
3. If your TriSensor has been successfully factory reset from its previous network, the LED will become a solid
yellow when you tap its Action Button. If this has failed, the LED will become a solid purple color for 2 seconds
when you tap the Action Button.
Removing your TriSensor from Z-Wave Network.
Your TriSensor can be removed from your Z-Wave network at anytime.You'll need to use your Z-Wave network's main
controller to do this and the following instructions tell you how to do this using Aeotec by Aeon Labs' Z-Stick and
Minimote controllers. If you are using other products as your main Z-Wave controller, please refer to the part of their
respective manuals that tells you how remove devices from your network.
If you're using a Z-Stick:
1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Take your Z-Stick to your TriSensor.
3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release.
4. Press the Action Button on your TriSensor 3x times within 2 seconds. The LED on TriSensor will become a solid
purple color.
5. If your TriSensor has been successfully removed from your network, the LED will flash white, green, white, green
(white, then green 2x times).
6. Press the Action Button on the Z-Stick to take it out of removal mode.