Ariston ST 100 ProTech Instrukcje instalacji, serwisowania i użytkowania - Strona 17

Przeglądaj online lub pobierz pdf Instrukcje instalacji, serwisowania i użytkowania dla Podgrzewacz wody Ariston ST 100 ProTech. Ariston ST 100 ProTech 36 stron. Unvented hot water storage cylinders
Również dla Ariston ST 100 ProTech: Instrukcja instalacji i użytkowania (24 strony), Podręcznik użytkownika (16 strony), Instrukcje instalacji, serwisowania i obsługi (34 strony)

Ariston ST 100 ProTech Instrukcje instalacji, serwisowania i użytkowania
The electrical installation must be in accordance with the current I.E.E.
3.13 e
lectricAl
wiring regulations.
c
onnection
protecH electronic Anti-corrosion systeM (st 100 models
only)
: The ProTech anti-corrosion system MUST be permanently
i
MportAnt
connected to a fused non-switched 240V electricity supply.
The ProTech system, an exclusive solution, is an electronic anti-corrosion
protection system which ensures maximum longevity of the appliance. The
electronic circuit creates a difference in potential between the hot water tank
and the titanium electrode, thereby guaranteeing optimum protection of the
tank and preventing corrosion.
Note: Do not use a water softner on products with the ProTech anti-
corrosion system.
To ensure the proper operation of the protection system, it Must Be
perMAnently connecteD to A FuseD non-switcHeD 240v, 3A
electricity supply even in the event of shut-down of the system. To
prevent risk to the appliance's lifespan when disconnecting the protection
system for an extended period of time, it is necessary to drain the appliance
beforehand.
In addition to the 240V network, the electronic circuit is also connected to
the tank, which is to be protected, and to the titanium protection electrode,
inForMAtion For tHe enD user
Proper operation of the protection system is shown by a continuous green
L.E.D, indicating that the circuits terminals are being supplied with electricity.
In the event of failure, a red LED indicates that there is a short-circuit
between the electrode and the cylinder tank, that one of the leads (tank or
electrode) is disconnected or that there is no water in the cylinder.
Your appliance is thus properly protected when the green L.E.D. is
illuminated and the red LED is off. Should this not be the case or should the
green and red LED light simultaneously, please contact your installer.
Direct systeMs
A mains supply of 240V, 3kW (13 amps) is required. Heat resistant cable,
round 3 or 4 core 2.5mm
2
(to BS6141 table 8) must be used to connect the
electrical supply through the Economy 7 time control switch using either
system 'A' or 'B' as illustrated in Fig. 3.12.
17