ABB ACH580 Series Skrócona instrukcja obsługi - Strona 3

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Jednostka sterująca ABB ACH580 Series. ABB ACH580 Series 15 stron. Floating point control
Również dla ABB ACH580 Series: Jak skonfigurować (2 strony)

ABB ACH580 Series Skrócona instrukcja obsługi
EN – Quick start-up guide
This guide describes how to start-up the drive using the First start assistant on the
Hand-Off-Auto control panel. For complete information on start-up, see ACH580
firmware manual (3AXD50000027537 [English]).
EN – Quick start-up guide
Note: Automatic selection of supply voltage is not supported in ACH580-31. You must
select the supply voltage manually using parameter 95.01. See steps for
This guide describes how to start-up the drive using the First start assistant on the
Hand-Off-Auto control panel. For complete information on start-up, see ACH580 firmware
Commissioning with parameters
manual (3AXD50000027537 [English]).
Note:
Start-up with the First start assistant on an Hand-Off-Auto
Automatic selection of supply voltage is not supported in ACH580-31. You must select the
control panel
supply voltage manually using parameter 95.01. See steps for Commissioning with
parameters on page 9.
Start-up with the First start assistant on an Hand-Off-Auto
Do not start-up the drive unless you are a qualified electrician.
control panel
Read and obey the instructions in chapter Safety instructions at the beginning of the
Hardware manual of the drive. Ignoring the instructions can cause physical injury or death, or
damage to the equipment
WARNING!
Check the installation. See chapter Installation checklist in the Hardware manual of the
Do not start-up the drive unless you are a qualified electrician.
drive.
Read and obey the instructions in chapter Safety instructions at the beginning of the Hardware manual of the
Make sure there is no active start on (DI1 in factory settings, that is, HVAC default).
drive. Ignoring the instructions can cause physical injury or death, or damage to the equipment.
The drive will start up automatically at power-up if the external run command is on
Check the installation. See chapter Installation checklist in the Hardware manual of the drive.
and the drive is in the external control mode.
WARNING!
Check that the starting of the motor does not cause any danger.
The drive will start up automatically at power-up if the external run command is on and the drive
De-couple the driven machine if
is in the external control mode.
Check that the starting of the motor does not cause any danger.
• there is a risk of damage in case of an incorrect direction of rotation, or
De-couple the driven machine if
• a Normal ID run is required during the drive start-up, when the load torque is higher
• there is a risk of damage in case of an incorrect direction of rotation, or
than 20% or the machinery is not able to withstand the nominal torque transient during
• a Normal ID run is required during the drive start-up, when the load torque is higher than 20% or the
the ID run.
machinery is not able to withstand the nominal torque transient during the ID run.
The two commands at the bottom of the display (Options
The two commands at the bottom of the display
and Menu in the figure on the right), show the functions of
(Options and Menu in the figure on the right),
the two softkeys
show the functions of the two softkeys
The commands assigned to the softkeys vary depending on
the context.
located below the display. The commands
assigned to the softkeys vary depending on the
Use keys
change values depending on the active view.
context.
Key
shows a context-sensitive help page.
Use keys
,
For more information, see ACS-AP-x assistant control panels
and/or change values depending on the active
user's manual (3AUA0000085685 [English]).
view.
Key
?
shows a context-sensitive help page.
For more information, see ACX-AP-x assistant
control panels user's manual (3AUA0000085685
[English]).
on page 9.

Hints on using the assistant control panel

Hints on using the assistant control panel
and
located below the display.
,
,
and
to move the cursor and/or
,
and
to move the cursor

Safety

Safety
and
EN – Quick start-up guide 3
R0-
R4
EN
EN
DA
DE
ES
FI
FR
IT
NL
PL
PT
RU
SV
TR
ZH