Supplied By www.heating spares.co Tel. 0161 620 6677
Z
Fig. 1.39
Fig. 1.41
A2
Fig. 1.42
Removing the pump
1. Unscrew "Z" and remove the electrical connection
(see fig. 1.39) ;
2. Release the nuts "A1" and remove the pump
(see fig. 1.40) .
A1
A1
Removing the pressure gauge
1. Remove the pressure gauge cover by pulling
(see fig. 1.41) ;
2. Release coupling "A2" using a 14 mm open ended
spanner (see fig. 1.42) ;
3. Push the pressure gauge through the control panel
from the rear (see fig. 1.43) .
Fig. 1.40
Fig. 1.43