Ariston microSYSTEM 28 RFFI Instrukcja instalacji - Strona 24
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Kocioł Ariston microSYSTEM 28 RFFI. Ariston microSYSTEM 28 RFFI 48 stron. Microsystem
Również dla Ariston microSYSTEM 28 RFFI: Podręcznik użytkownika (16 strony), Instrukcja instalacji (24 strony)
6.
TECHNICAL INFORMATION
CE Certification
Heat Input
Heat Output
Efficiency of Nominal Heat Input
Efficiency at 30% of Nominal Heat Input
Heat Loss to the Casing (∆T=50°C)
Flue Heat Loss with Burner Operating
Flue Heat Loss with Burner Off
Maximum Discharge of Fumes (G20)
Residual Discharge Head
Consumption at Nominal Capacity(G20)
Gas Consumption after 10 Minutes*
(15°C, 1013 mbar) (G30-G31)
Temp. of exhaust fumes at nominal capacity °C
CO
Content
2
O
Content
2
CO Content
Minimum Ambient Temperature
Head Loss on Water Side (max) (∆T=20°C) mbar
Residual Head of System
Heating Temperature
Expansion Vessel Capacity
Expansion Vessel Pre-load Pressure
Maximum Water Content of System
Maximum Heating Pressure
Nominal Pressure
Electrical Supply
Power Consumption
Protection Grade of Electrical System
Internal Fuse Rating
Weight
G.C. Number
*Calculated at 70% maximum output
Manufacturer:
Commercial subsidiary: MTS (GB) LIMITED
Natural Gas (G20) mbar
LPG (G30-G31)
Merloni TermoSanitari SpA - Italy
MTS Building
Hughenden Avenue
High Wycombe
Bucks HP13 5FT
Telephone: (01494) 755600
Fax: (01494) 459775
Internet: http://www.mtsgb.ltd.uk
E-mail: [email protected]
Technical Service Hot Line: (01494) 539579
63AU4549
max/min kW
max/min kW
%
%
%
%
%
Kg/h
mbar
m
3
/h
m
3
Kg/h
%
%
ppm
°C
bar
max/min °C
l
bar
l
bar
mbar
V/Hz
W
IP
FAST 2 AT
Kg
21 RFFI
63AU4549
22.7/10.0
21.0/8.7
92.8
90.8
1.2
6.0
0.2
46.2
0.70
2.4
0.32/0.39
1.78/1.76
117.2
6.81
9
20
+5
200
0.25
82/42
6
1
130
3
20
30-37
230/50
155
X4D
FAST 2 AT
39
41-116-06
41-116-07
28 RFFI
29.8/12.0
27.8/10.5
93.5
90.7
0.2
6.3
0.4
60
1.60
3.15
0.37
2.34/2.31
128.8
6.9
8.1
48
+5
200
0.25
82/42
6
1
130
3
20
30-37
230/50
155
X4D
39