Ariston CP 859 MT X AUS S Instrukcje użytkowania i instalacji - Strona 9

Przeglądaj online lub pobierz pdf Instrukcje użytkowania i instalacji dla Piekarnik Ariston CP 859 MT X AUS S. Ariston CP 859 MT X AUS S 13 stron. Cooker and oven
Również dla Ariston CP 859 MT X AUS S: Specyfikacje (13 strony), Instrukcja obsługi (16 strony)

Ariston CP 859 MT X AUS S Instrukcje użytkowania i instalacji
The following instructions are provided for qualified
installers so that they may accomplish installation,
adjustment and technical maintenance operations correctly
and in compliance with current regulations and standards.
Important: the appliance should be disconnected from
the mains electricity supply before any adjustment,
maintenance, etc. is carried out. Maximum caution should
be used should it be necessary to keep the appliance
connected to the electricity supply.
The dimensions of the appliance are given in the figure on
page 2. For trouble-free operation of appliances installed
in housing units, the minimum distances shown in fig.5
should be observed. Adjacent surfaces and the wall at the
rear should also be able to withstand an overheating
temperature of 65 °C.
fig.6
fig.5
Prior to installing the cooker, 95 ÷ 155 mm high supporting
feet (provided) should be fitted into the holes to be found
in the bottom of the cooker (fig.6). These feet are screw-
adjustable and whenever necessary should be used to
make sure the cooker stands level.
Positioning
This appliance may only be installed and operated in
permanently ventilated rooms in compliance with current
standards. The following requirements must be observed:
• The appliance must discharge combustion products into
a special hood, which must be connected to a chimney,
flue pipe or directly to the outside (fig.7).
• If it is impossible to fit a hood, the use of an electric fan
is permitted, either installed on a window or on an external
wall, which must be switched on at the same time as the
appliance.
Kitchen ventilation
The air flow into the room where the appliance is installed
must equal the quantity of air that is required for regular
combustion of the gas and for ventilating the same room.
Air must be taken in naturally through permanent apertures
made in the outside walls of the room or through single or
branching collective ventilation ducts in compliance with
current standards and regulations. The air must be taken
directly from the outside, from an area far from sources of
pollution. The ventilation aperture must have the following
characteristics (fig.8A):

INSTALLATION

In a chimney stack or branched flue
(exclusively for cooking appliances)
• total free cross section of passage of at least 6 cm² for
every kW of rated heating capacity of the appliance, with
a minimum of 100 cm² (the heating capacity is indicated
on the rating plate);
• it must be made in such a way that the aperture, both on
the inside and outside of the wall, cannot be obstructed;
• it must be protected, e.g. with grates, wire mesh, etc. in
such a way that the above-mentioned free section is not
reduced;
• it must be situated as near to floor level as possible.
Examples of ventilation holes
for comburant air
The air inflow may also be obtained from an adjoining room,
provided the latter is not a bedroom or a room where there
is a risk of fire, such as warehouses, garages, fuel stores,
etc. and is ventilated in compliance with the current
standards and regulations. Air from the adjoining room to
the one to be ventilated may be made to pass freely through
permanent apertures with a cross section at least equal to
that indicated above. These apertures may also be obtained
by increasing the gap between the door and the floor
(fig.8B). If an electric fan is used for extracting the
combustion products, the ventilation aperture must be
increased in relation to its maximum performance. The
electric fan should have a sufficient capacity to guarantee
an hourly exchange of air equal to 3 ÷ 5 times the volume
of the kitchen. Prolonged, intensive use of the appliance
may require extra ventilation, e.g. an open window or a
more efficient ventilation system by increasing the
extraction power of the electric fan if installed. Liquid
petroleum gas descends towards the floor as it is heavier
than air. Apertures in the outside walls in rooms containing
LPG cylinders should therefore be at floor level, in order to
allow any gas from leaks to be expelled. Do not store LPG
cylinders (even when empty) in basements or rooms below
ground level; it is advisable to keep only the cylinder in use
in the room at any one time and connected far from heat
sources which could raise its temperature to above 50 °C.
8
fig.7
Detail A
Adjacent
A
Enlarging the ventilation slot
fig. 8A
Directly to the outside
Room to be
room
ventilated
between window and floor
fig. 8B
AUS