At the end of the function, when end of function conditions are met, the appliance emits an acoustic signal
and the led starts flashing, alerting the user to remove the bottle. To exit the function, the user must press
the button until the function led indicator stops flashing.
The function cannot be activated in an alarm condition or in tandem with the HOLIDAY function. Activation
of the HOLIDAY function automatically deactivates the ICE PARTY function and activates the
corresponding buzzer and led, prompting the user to remove the bottle.
The I CARE or SUPER FREEZER functions can be activated but will start at the end of the ICE PARTY
function.
IMPORTANT: In the event of a power failure during the I CARE function, when the power supply is
restored the function will not be reactivated and the end of function signal will be activated
immediately.
Super Freeze Function:
See the Super Freeze function of the Indesit New Electronic Cold Platform (24 hour version for
No Frost models and 24/48 hour version for Static models).
Super Fridge Function:
See the Super Fridge function of the Indesit New Electronic Platform.
Child Lock:
The Child Lock function is designed to prevent accidental changes to appliance settings.
To activate the function, press and hold the "Alarm" button for two seconds, the display shows
"LO CH" and the buzzer emits a short beep. The appliance shows "LO CH" on the display for the time
parameterised in the EEPROM memory while the function remains active.
The function is deactivated by pressing the "Alarm" button again for two seconds. The buzzer beeps and
the message "CH OF" appears on the display, confirming exit from the function.
In the event of a temperature alarm, an Ever Fresh or door open alarm, or if the ICE-PARTY function ends
or a Fault is detected, these situation take priority, halting and deactivating the Child Lock. When the alarm
situation is over, the Child Lock function WILL NOT be reactivated automatically.
In the event of a power failure, when power is restored the function will be reactivated automatically.
I CARE:
For appliances with control knob interface, the I CARE function, featured on the Ariston New
Electronic Cold Platform, is identical to the ECO function on the Indesit New Electronic Cold
Platform.
For appliances with TOUCH interface, this function is activated automatically when the appliance is
switched on. The Auto led also lights up automatically, only switching off if and when the user changes
the preset temperature.
If the user changes the temperature and later reverts to the temperatures managed by I CARE manually,
the Auto led will not light up again and the PCB will not switch the solenoid valve before switching off the
compressor at the end of the cooling demand from the fridge compartment. In short, the appliance will
operate as a normal appliance with normal temperature settings. To once again activate function, the user
must set the I CARE function by pressing the relative button.
The temperature bands can be changed without exiting the I CARE function.