Whirlpool 3RLEC8600 Instrukcja instalacji
Product Dimensions
Dimensions shown with feet extended 2,5 cm (1") from bottom of dryer.
27,9 cm
(11")
109,5 cm
¹⁄₈
(43
")
97,2 cm
¹⁄₄
(38
")
74,3 cm
¹⁄₄
(29
")
Side swing door clearances
57,8 cm (22
Location must be large enough to fully open dryer door.
Exhaust dimensions
10 cm
(4")
35,9 cm
(14¹⁄₈")
back exhaust
4
terminal block cover
power supply
cord/cable
strain relief
35,6 cm
(14")
The dryer door
extends
35,6 cm (14")
from the front
of the dryer
when fully
opened.
68,6 cm (27")
³⁄₄
")
⁷⁄₈
9,8 cm (3
")
48,9 cm
¹⁄₈
(19
")
³⁄₄
57,8 cm (22
")
10,8 cm
(4¹⁄₄")
26 cm
(10 ¹⁄₄")
left or right
side exhaust

Electrical Requirements

This dryer is supplied without an electric cord and plug. It must
be connected by a competent electrician to a single-phase
electricity supply at the voltage shown on the dataplate, using a
suitable fixed wiring installation in accordance with local and
national wiring regulations.
A 3-wire circular cord of minimum conductor size 2.5 mm
cross-section area should be used.
A 30A supply fuse should be used, and a switch with a
minimum contact separation of 3 mm in both poles must be
incorporated into the fixed wiring for dryer disconnection. The
dryer should be positioned so that the disconnection switch is
easily accessible to the user.
A cord clamp bush is provided on the dryer, and should be
tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made in
accordance with the terminal markings. Remember to replace
the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(89/336/EEC) the maximum electricity supply system impedance
to which the electric dryer should be connected is declared to be
0.302 Ohm + j0.189 Ohm.
WARNING
Electric Shock Hazard
Electric earthing is required on this dryer.
Do not earth to a gas pipe.
Do not have a fuse in the neutral or earthing circuit
Check with a qualified electrician to be sure the dryer is
properly earthed.
Failure to follow these instructions could result in
death, fire, or serious injury.
If codes permit and an additional earth bond wire is used, it is
recommended that a competent electrician determine that the
earth bond path is adequate.