Whirlpool 7MWGD1860EM0 Instrukcja instalacji - Strona 26
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Suszarka Whirlpool 7MWGD1860EM0. Whirlpool 7MWGD1860EM0 28 stron.
Make Gas Connection
1.
Connect gas supply to dryer
Flared
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON
tape.
®†
2.
Plan pipe fitting connection
A
B
A. 3/8" flexible gas connector
B. 3/8" dryer pipe
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
26
Non-flared
B
male fitting
C
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
Open valve
B
1.
Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2.
Move dryer to final location
D
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.