Whirlpool Cabrio WGD6600VU1 Instrukcja obsługi i konserwacji - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Suszarka Whirlpool Cabrio WGD6600VU1. Whirlpool Cabrio WGD6600VU1 48 stron. Steam fabric care system gas dryer

Whirlpool Cabrio WGD6600VU1 Instrukcja obsługi i konserwacji
Parts needed:
Check local codes and consult gas supplier. Check existing gas
supply, electrical supply and venting, and read "Electrical
Requirements,"
"Gas Supply Requirements"
and "Venting
Requirements"
before purchasing parts.
Mobile home installations require special parts (listed following)
that may be ordered by calling the dealer from whom you
purchased your dryer. For information on ordering, please refer to
the "Assistance
or Service" section. You may also contact the
dealer from whom you purchased your dryer.
Mobile home installation kit. Ask for Part Number 346764.
Metal exhaust system hardware.
I
i
±
"
Explosion
Hazard
Keep flammable
materials
and vapors,
such as
gasoline,
away from dryer,
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need
A location that allows for proper exhaust installatien. See
"Venting Requirements."
A separate 3O-amp circuit.
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of
200 Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered.
Cold water faucets located within 4 ft (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (138-6_)0 kPa). You
may use the water supply for your washer using the "Y"
connector and short hose (if needed) which are provided.
20-100 psi (138-690 kPa) for best performance.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning
appliance can be installed in the
same closet as a dryer.
Installation
Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
72V4"
',55.5cm)
*Most installations require a minimum 5" (12.7 el) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation
spacing
for recessed
area or closet
installation
The following spacing dimensions are recommended
for this
dryer. This dryer has been tested for spacing of 0" (0 cm)
clearance on the sides and rear. Recommended
spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Additional spacing is required if you exhaust out the rear of
the dryer to either the right or left side.
18";_
(4s.7 cm)
3L
omo
m
(2,Sofa)
(73.7 Crn)
(2.8 cnl)
(2.86fn)(74.3 Crn)(12,7cm)
A
B
m
14" n_*
48in?*,
I_10crn_l
[
#
241n,'*
C
17._cm/
_
3,,_
(75crn)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Mobile home - Additional
installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240
MH.