Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Suszarka Whirlpool CGM2761TQ0. Whirlpool CGM2761TQ0 36 stron. Commercial gas or electric dryer

2, Remove hold-down screw andtheterminal block cover.
_D
J
J
3,
Assemble ¾" UL-tisted strain relief (UL marking on strain
relief,I into the hole below the terminal block opening. Tighten
strain relief screws just enough to hold the two clamp
sections together. Install power supply cord through the
A, External ground conductor screw
B. Tab
C, Terminal block cover
D. Hold-down screw
A, Strain relief clamp sections
B, Dryer cabinet
C, Strain relief screws
4,
strain relief.
Complete installation following instructions for your type of
electrical connection:
Four-wire (recommended method)
Three-wire (if four-wire is not available)
Power
Supply
Cord,
Four-wire
electrical
connection:
B
J
A, Spade terminals with upturned ends
E
B. Neutral
C. 3/4"UL-//sted strain relief
D. Neutral (white)
E. Ring terminals
F, Ground wire
G, Ground prong
Four-wire power supply cord must have four,
No.-!0 copper wires and match a four-wire
receptacle of NEMA Type 14-30R. The
fourth wire (ground conductor) must be
identified by a green cover and the neutral
conductor by a white cover.
5, Remove the center terminal block screw.
6, Remove the appliance neutral ground wire
from the external ground conductor screw.
Fasten under center, silver-colored
terminal block screw.
7, Connect the ground wire of the power
supply cord to the external ground
conductor screw. Tighten screw.
8, Connect the neutra! wire (white or center)
of the power supply cord under the center
screw of the terminal block. Tighten
screw.
9, Connect the other wires to outer terminal
block screws. Tighten screws.
10, Tighten strain relief screws.
11, Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
SB
A
t:"
................
_t
.......
_
mm
I
D
E
................
A, External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Strain relief screw
F, Neutral (center wire)
G, Ground wire