Whirlpool CGM2793BQ Instrukcja instalacji - Strona 19

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Suszarka Whirlpool CGM2793BQ. Whirlpool CGM2793BQ 48 stron. Commercial dryer gas or electric
Również dla Whirlpool CGM2793BQ: Instrukcja instalacji (48 strony)

Whirlpool CGM2793BQ Instrukcja instalacji
ELECTRIC DRYER ELECTRICAL
CONNECTIONS
(FOR
U.S.A.
ONLY)
Connection
Options
Power Cord
4-wire receptacle (NEMA Type 14-30R)
(127
3-wire receptacle (NEMA Type 10-30R)
3-wire direct
Connecting
4-Wire
Connection:
Power Supply
Cord
IMPORTANT: A 4-wire connection
is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Standard
Power Supply Cord Connectors
Flanged Spade Connector
Ring Connector
Connecting
Neutral Ground and Neutral Wires
1. Remove center terminal block screw (A) and the neutral
ground wire (B) by removing the green external ground
conductor
screw (C).
I
2. Connect neutral ground wire (B) and neutral wire (white or
center wire) (D) of power supply cord under center terminal
block screw (A). Tighten screw.
Connecting
Direct Wire Ground
3. Connect ground wire (green or bare) (E) of power supply cord
under green external ground conductor screw (C). Tighten
screw.
Connecting
Remaining
Wires
4. Connect remaining wires under outer terminal block screws
(F). Tighten screws. Finally, reinstall terminal block to dryer
rear panel. Secure cover with hold-down
screw.
19