4" (102 mm) heavy metal exhaust vent and clamps must be
used.
4" (102 mm) heavy metal exhaust vent
Vent products can be purchased from your dealer or by calling
Whirlpool Service. For more information, see the "Assistance or
Service" section.
Rigid metal vent
■
For best drying performance, rigid metal vents are
recommended.
■
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
■
Flexible metal vents are acceptable only if accessible for
cleaning.
■
Flexible metal vent must be fully extended and supported when
the dryer is in its final location.
■
Remove excess flexible metal vent to avoid sagging and kinking
that may result in reduced airflow and poor performance.
■
Do not install flexible metal vent in enclosed walls, ceilings, or
floors.
■
The total length of flexible metal vent should not exceed
7¾ ft. (2.4 m).
Elbows
45° elbows provide better airflow than 90° elbows.
Good
Clamps
■
Use clamps to seal all joints.
■
Exhaust vent must not be connected or secured with screws or
other fastening devices that extend into the interior of the duct
and catch lint. Do not use duct tape.
4"
102 mm
Better
Clamp
Exhaust
A and B: Recommended hood styles.
C: Acceptable hood style.
B
A
4"
(102 mm)
4"
(102 mm)
A. Louvered hood style
B. Box hood style
C. Angled hood style
■
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
■
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
■
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other
installations are possible.
A
A. Dryer
E. Clamps
B. Elbow
F. Rigid metal or flexible metal vent
C. Wall
G. Vent length necessary to connect elbows
D. Exhaust hood
H. Exhaust outlet
C
4"
(102 mm)
2½"
(64 mm)
B
C
D
E
F
G
H
11