Przeglądaj online lub pobierz pdf Instrukcje instalacji oraz instrukcja obsługi i konserwacji dla Okap wentylacyjny Whirlpool 30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNTCANOPY RANGE HOOD. Whirlpool 30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNTCANOPY RANGE HOOD 28 stron. 30" and 36" (76.2 and 91.4 cm) wall-mount canopy range hood
Również dla Whirlpool 30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNTCANOPY RANGE HOOD: Instrukcja instalacji (28 strony)

Whirlpool 30
Example Vent System
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).
1 - 90° elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)

Electrical Requirements

Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit
is required.
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating
of the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located behind the left filter
on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
6

INSTALLATION INSTRUCTIONS

Wall cap
It is recommended that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or
non-vented.
3. Select a flat surface for assembling the range hood.
Place covering over that surface.
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where
the canopy hood will be installed.
2. Select a mounting height between a minimum of 24"
(61.0 cm) for an electric cooking surface, a minimum of
27" (68.6 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood. Mark a reference line on the wall.
3. Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with
the centerline marked on the wall.
4. Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood where possible. If there is no wood to screw into,
additional wall framing supports may be required, or use the
(4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws.
Remove the template.

Prepare Location

WARNING
Excessive Weight Hazard
A
D
R
L I
L
2
T (
W
O
)
3
1 /
6
"
P
L I
O
T
H
O
L
E
S
T
H
R
O
U
G
H
S
T
U
D
S
O
R
R
E
A
R
W
A
L
L
S
U
P
P
O
R
T
M
O
U
C
L
n I
s
a t
l
a l
t
o i
n
H
e
g i
H
o
i r
o z
n
a t
l
L
n i
e
B
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
R
E
A
R
W
A
L
L
N
T
N I
G
T
E
M
P
L
A
T
E
A
L
G I
N
B
O
T
T
O
M
E
D
G
E
W
T I
H
P
E
N
C
L I
L
N I
E
N I
D
C I
A
T
N I
G
B
O
T
T
O
M
O
F
T
H
E
H
O
O
D
h
t
C