lnstrudions for Installation
Install range hoods in accordance with the manufacturer's instructions� The
range hood clearance should ha ve a minimum 650mm to 700mm from the
top of the cooking surface to the underside of the Hood�
WARNING: DO NOT penetrate any screws into the range hood as this may
result in electrical hazards.
WARNING: Failure to install the screws or fixing device in accordance with
these instructions may result in electrical hazards.
If a connection flue composed of two parts is used, the upper part must be
placed outside the lower part�
Exhaust air must not be discharged into a flue which is used for exhausting
fumes from appliances burning gas or other fuels� Installation must comply
with any local regulations concerning the discharge of exhaust air�
Before proceeding with the assembly, remove the anti-grease filter(s) (Fig.5)
so that the unit is easier to handle� Prepare the hole in the ceiling or wall for
the evacuation of the air.
Fig�5
Fixing to the Wall
Position the hood, then mark and drill the holes (A) according to the
distances indicated (Fig�6)�