Whirlpool GZ8330 Series and Instrukcje instalacji oraz instrukcja obsługi i konserwacji - Strona 3

Przeglądaj online lub pobierz pdf Instrukcje instalacji oraz instrukcja obsługi i konserwacji dla Okap wentylacyjny Whirlpool GZ8330 Series and. Whirlpool GZ8330 Series and 20 stron. 30" and 36" convertible range hood
Również dla Whirlpool GZ8330 Series and: Instrukcje instalacji oraz instrukcja obsługi i konserwacji (10 strony)

Whirlpool GZ8330 Series and Instrukcje instalacji oraz instrukcja obsługi i konserwacji
Wire sizes must conform to the
requirements of the National
Electrical Code ANSI/NFPA 70 —
latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code
Part 1 and C22.2 No. 0-M91 - latest
edition** and all local codes and
ordinances.
A U.L.- or C.S.A.-listed conduit
connector must be provided at each
end of the power supply cable (at
the range hood and at the junction
box).
In U.S. only: For power cord
connected installations, a U.L.-
listed range hood cord-connection
kit MUST be used. Cord kit has not
been evaluated for use in Canada.
Copies of the standards listed may be
obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

Venting requirements

Venting system must terminate to
the outside.
Do not terminate the vent in an attic
or other enclosed space.
Do not use four-inch (10.2 cm)
laundry-type wall caps.
Do not use plastic vent.
Vent system needed for installation
is not included.
Determine which outside venting
method needs to be used. It is
recommended that the vent
system be installed before
installing the hood.
NOTE: If a non-vented
(recirculating) installation is
desired, follow instructions on
Page 5.
The length of the vent system and
number of elbows should be kept
to a minimum to provide efficient
performance. The size of the vent
system should be uniform. Do
Not install two elbows together.
Use duct tape to seal all joints in
the vent system. Vent system can
terminate either through the roof
or wall. Use caulking to seal
exterior wall or roof opening
around exhaust hood. For the
most efficient and quiet operation,
it is recommended that the range
be vented vertically through the

Product dimensions

1-1/2"
(3.8 cm)
12"
(30.5 cm)
9"
(22.9 cm)
2"
(5.1 cm)
9"
(22.9 cm)
3/4"
(1.9 cm)
7-1/2"
(19.1 cm)
29-7/8" (75.9 cm) model: GZ8330
35-7/8" (91.1 cm) model: GZ8336
roof through 6" (15.2 cm) round
vent system.
Figures 1 and 2 show common
venting methods and what types
of materials are needed.
Vertical roof venting
6" (15.2 cm) or larger
round or 3-1/4" x 10"
(8.3 x 25.4 cm)
through roof
transition piece
27" (68.6 cm) to
33" (83.8 cm) above
cooking surface
Figure 1
1"
(2.5 cm)
1-1/2"
(3.8 cm)
3/8"
(9.5 mm)
Recommended vent length
Use 3-1/4" x 10" (8.3 x 25.4 cm) or
6" (15.2 cm) or larger round vent
with a maximum length of 70 feet
(21.3 m) for vent system. If 7"
(17.8 cm) round vent is used, the
maximum length is 80 ft. (24.4 m).
For best performance, use no
more than three 90° elbows. To
calculate the length of system
you need, add the equivalent feet
(meters) for each vent piece used
in the system. See the examples
on the next page.
Horizontal wall venting
roof cap
6" (15.2 cm) or larger
round or 3-1/4" x 10"
(8.3 x 25.4 cm)
through the wall
3-1/4" x 10"
(8.3 x 25.4 cm)
through the wall
27" (68.6 cm) to
33" (83.8 cm) above
cooking surface
20"
(50.8 cm)
wall
cap
Figure 2
3