WARNING
Electrical Shock Hazard
Disconnect power before making
electrical connections.
Connect ground wire to green ground
screw in terminal box.
Failure to do so can result in death or
electrical shock.
to light
ground
bulbs
wires
power
white wires
supply
wiring
18.
For models requiring direct wiring:
Connect white wiring from the terminal box,
light harness and power supply wiring
together with twist-on connector.
Connect black wiring from the terminal box
to power supply wiring with twist-on
connector.
Connect the power supply ground wire and
the green ground wire inside the terminal
box under the terminal box ground screw.
Use caulking to seal wire opening.
Replace terminal box cover.
For cord connected models:
WARNING
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can
result in death, fire, or electrical shock.
For your personal safety, this range hood
must be grounded. To minimize possible
shock hazard, the cord must be plugged
into a mating, 3-prong, ground-type outlet,
grounded in accordance with National
Electrical Code, ANSI/NFPA 70 – latest
edition* and all local codes and
ordinances.
If mating outlet is not available, it is the
responsibility and obligation of the
customer to have a properly grounded, 3-
prong outlet installed by a qualified
electrician.
Do not use an extension cord.
Using a U.L.-listed power supply
cord-connection kit:
Follow Power Cord Kit instructions for
connecting wiring.
Replace terminal box cover.
19.
Turn power supply on.
Panel D
Venting through
the wall
wiring knockout
10a.
knockout behind it. Remove top or rear
wiring knockout as needed.
terminal
box
connector
blower
wiring
connector
11a.
black wires
Attach the exhaust vent connection to the
range hood. Check that the damper blade
twist-on
rotates up and down freely, if used.
connectors
12a.
Remove the screw
holding the terminal
box cover. Remove
cover.
Use two or more people to move and
install range hood.
Failure to follow this instruction can
result in back or other injury.
13a.
Lift the range hood into final position and
center. Mark on the underside of cabinet
the location of the four keyhole mounting
slots and the wiring knockout. On some
cabinets, filler blocks may need to be
added for range hood to attach to cabinet.
Set range hood aside on a protected
surface.
wall vent
knockout
wiring knockout
Remove the wall vent
knockout and the inner
damper blade
(remove if wall
cap has damper
blade)
WARNING
Excessive Weight Hazard
keyhole slot
14a.
Do Not turn on power until
installation is complete.
Run wiring through wall or cabinet
according to the National Electrical Code
and local codes and ordinances.
keyhole slot
outline
15a.
Start screws into neck area
of each of the four
keyhole mounting screw slots marked on
the cabinet bottom.
16 a.
Lift range hood into final
position, feeding electrical
wire through wiring opening. Position the
range hood so that the large end of the
keyhole slots are over the screws. Then push
the hood toward the wall so that the
screws are in the neck of the slots. Tighten
mounting screws to cabinet, making sure
mounting screws are in narrow neck of
slots. Make sure that damper blade rotates
up and down freely.
terminal box
5"
17a .
Reinstall blower back into
position. Snap blower wire
retainer back into blower housing indents.
Reconnect the blower wiring connector
back into the terminal box connector plug.
screw
3"