Whirlpool RJH 3330-1 Instrukcja instalacji i obsługi - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Okap wentylacyjny Whirlpool RJH 3330-1. Whirlpool RJH 3330-1 6 stron. Whirlpool microshelf hood installation and operating instructions rjh 3330-1

Whirlpool RJH 3330-1 Instrukcja instalacji i obsługi
-
-
-;
THICK
SHEET
ROCK
2s'
SCREW,
NO. IO
<.
U
HOLLOW
WALL
ANCHOR
BOLT
Figure 5
9.
Remove all 4 screws from the anchor
bolts.
10.
Attach
hanging
bracket to the wall with the
four screws taken from the anchor
bolts. Tighten
the screws
in the anchor
bolts until the anchor
bolts are completely
set.
11.
Install
four
remaining
'/4" dia.
lag
bolts
through
the hanging
bracket
and into the two
studs.
CAUTION:
Do not overtighten
the lag screws. If
they are overtightened,
the bracket may pull into
the wall material which will not allow the shelf to
slide into place properly.
12.
The hole in the bottom of the cabinet (for the
duct provided
with the hood)
should
be cut as
shown in Figure 6 (15%" long by 1%" deep). Hole
must be cut to back wall. Make sure to center the
hole within
the 30" allotted
space.
L
HANGING
BRACKET
Figure 6
13.
Rough wire the electrical
supply
to the area
shown in Figure 3.
14.
Hang the shelf hood on the hanging
bracket.
(See Figure 10). To be sure theshelf
hood hanging
angle
is completely
engaged
in the
hanging
bracket, measure from the top of the shelf hood to
the top of the hanging
bracket.
This distance
should
be l-7/16"
on both ends.
CAUTION:
Do not
continue
until
both
ends
measure
l-7/16".
If the hanging
angle is not fully
engaged
in the hanging
bracket,
the Microshelf
Hood will not be level and the hood may become
dislodged
from the hanging
bracket.
This could
cause damage.
15.
Complete
the duct work by:
A.
Fit the duct provided
with the Microshelf
Hood on to the vent outlet of the Microshelf
hood.
B.
Mark and drill (2) %" dia. holes (1 each
side) to fasten the thin duct provided
with the
hood to the back wall. See Figure 7.
C.
Use 2 #8 x VI" long screws provided with
the unit to fasten the narrow thin duct to the
shelf. See Figure 7.
D.
Next install the transition
adaptor to the
thin duct.
This transition
adaptor will accept 3%" x 10"
duct.
E.
Complete
the
3%"
x
10"
duct
(or
equivalent)
to
the
outside
using
the
guidelines
listed under venting requirements.
B.
Connect
the electrical
supply:
It is the personal
responsibility
and obligation
of the
customer
to contact a qualified
installer
to assure that
the
electrical
installation
is adequate
and
is in
conformance
with the National
Electrical
Code and
local codes and ordinances.
Page 3