Whirlpool UXG7360VDS0 Instrukcja obsługi i konserwacji - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Okap wentylacyjny Whirlpool UXG7360VDS0. Whirlpool UXG7360VDS0 28 stron. 30" (76.2cm), 36" (91.4cm) and 48" (121.9cm) wall-mount canopy grill vent hood installation instructions

Whirlpool UXG7360VDS0 Instrukcja obsługi i konserwacji
4.
Run 3 wires, black, white and green, in 1/2"conduit from
service panel to terminal box. Use caulking to seal openings.
D
E
/
.......
ii H
A. Green (or bare) ground wire from home power
supply
connected to green
ground
screw
B. UL fisted wire connectors (3)
C. Black wires
D. Home power supply cable
E. Green ground screw
F. Grill vent hood power supply cable
G.Strain relief
H. White wires
5. Use UL listed wire connectors
and connect black wires (B)
together.
6. Use UL listed wire connectors
and connect white wires (H)
together.
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical
shock.
7. Connect green (or bare) ground wire from home power supply
to the unused green ground wire (A) in the terminal box.
8. Tighten strain relief screws.
9. Install terminal box cover.
10. Using the light bulb removal tool, check all light bulbs to
make sure they are secure in their sockets.
11. Reconnect power.
1.
DL_(,. .........................
t,_,J_..i_
I0/=_.>, I /I;CC@IIO[!I
I
Use 4 - #10 sheet metal screws to assemble the duct cover
sides to duct cover front.
/
2. From inside the grill vent hood, attach duct cover to the top of
the grill vent hood using 8 - #10 sheet metal screws.
See "Metal Grease Filters" in "Grill Vent Hood Care" section.
Check Grill Vent Hood Operation
1. Press the light button (B) to turn on the light, press again to
turn light off.
2. Press fan button (A) "up" to turn fan on Low Speed. Press the
fan button "down" to turn fan to High Speed.
3. Press fan button (A) to the middle position to turn off the fan.
4. If grill vent hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
8