INSTALLATION INSTRUCTIONS
NOTE: It is recommended
that the vent system be installed
before hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
1. Disconnect
power.
2. Depending on your model, determine which venting method
to use: roof, wall or non-vented (recirculating).
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
4. Lift the range hood and set it upside down onto covered
surface.
5. If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
Wood filler strips
(recessed
cabinet
bottoms only)
_:i!_
_i
7"6 ore)
J_:\\
___
\
3" (7.6 cm)
Wail
Determine Wiring Hole Location
Cut only one 1V4"(3.2 cm) diameter wiring access hole. See
Step 2 for wiring hole location instructions.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
A. Centerline
To wire through top:
1. Mark a line distance "A" from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
7/8"(2.2 cm) from back wall. Drill a 1W' (3.2 cm) diameter hole
through the cabinet at this point.
I
'1!
A
7/8" (2.2 cm)
from
waJJ_
not cabinet
frame
Centerline
A. 8%" (21.3 cm) for30"
(76.2 cm) models
11%" (28.9 cm) for36"
(91.4 cm) models
To wire through wall:
1. Mark a line distance "A" from the right of the centerline on the
underside of the wall. Mark the point on this line that
is 7/8"(2.2 cm) from the underside of the cabinet. Drill a
1V4" (3.2 cm) diameter hole through the rear wall at this point.
'11
Centerline
A. 8s/8'' (21.3 cm) for30"
(76.2 cm) models
11%" (28.9 cm) for36"
(91.4 cm) models
Style 1 - Cut Openings for 31/4" x 10" (8.3 cm x 25.4 cm)
Rectangular
Vent System
Roof Venting
To make a 41/4'' x 101/2 '' (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 1/2"(1.3 cm) and 43/4"(12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼ '' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.