Whirlpool WVW51UC6LS Instrukcje instalacji oraz instrukcja obsługi i konserwacji - Strona 5
Przeglądaj online lub pobierz pdf Instrukcje instalacji oraz instrukcja obsługi i konserwacji dla Okap wentylacyjny Whirlpool WVW51UC6LS. Whirlpool WVW51UC6LS 28 stron. 30" and 36" (76.2 and 91.4 cm) wall-mount canopy
15
/
" (38.7 cm)
1
4
* For non-vented (recirculating) installations
** For vented installations
Cabinet Dimensions
10" (25.4 cm) min.
13" (33.0 cm) max.
Side
cabinet
30" (76.2 cm) or
36" (91.4 cm)
"X"
bottom of
canopy
to cooking
surface
* For non-vented (recirculating) installations
IMPORTANT:
Minimum distance "X": 24" (61 cm)
from electric cooking surface
Minimum distance "X": 27" (68.6 cm)
from gas cooking surface
Suggested maximum distance "X": 36" (91.4 cm)
**27
/
" (68.9 cm) min.
1
8
**41
/
" (104.5 cm) max.
1
8
*27
/
" (68.9 cm) min.
1
8
*45
/
" (115.6 cm) max.
1
2
8" (20.5 cm) min.*
15
/
" (38.7 cm)* min.
1
4
Side
cabinet
Cooking surface
The chimneys can be adjusted for different ceiling heights.
See the following chart.
Vented Installations
Min. ceiling height
Electric cooking
7' 4" (2.23 m)
surface
Gas cooking
7' 7" (2.31 m)
surface
Non-Vented (Recirculating) Installations
Min. ceiling height
Electric cooking
7' 4" (2.23 m)
surface
Gas cooking
7' 7" (2.31 m)
surface
NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soffit heights depending on the distance
"X" between the bottom of the range hood and the cooking
surface. For higher ceilings, a Chimney Extension Kit is available
from your dealer or an authorized parts distributor. The chimney
extension replaces the upper chimney shipped with the range
hood. See the "Assistance or Service" section to order.
Venting Requirements
(vented models only)
■
Vent system must terminate to the outdoors except
for non-vented (recirculating) installations.
■
Do not terminate the vent system in an attic or other
enclosed area.
■
Do not use 4" (10.2 cm) laundry-type wall cap.
■
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
■
The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the Most Efficient and Quiet Operation:
■
Use no more than three 90° elbows.
■
Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
■
Do not install two elbows together.
■
Use clamps to seal all joints in the vent system.
■
The vent system must have a damper. If the roof
or wall cap has a damper, do not use the damper
supplied with the range hood.
■
Use caulking to seal exterior wall or roof opening
around the cap.
■
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Max. ceiling height
9' 5" (2.87 m)
9' 5" (2.87 m)
Max. ceiling height
9' 9" (2.97 m)
9' 9" (2.97 m)