Firesense LIP-10A-TGG-NTS-1 Podręcznik - Strona 15

Przeglądaj online lub pobierz pdf Podręcznik dla Grzejnik tarasowy Firesense LIP-10A-TGG-NTS-1. Firesense LIP-10A-TGG-NTS-1 17 stron. Outdoor patio heater

If you have any questions regarding this product, please call our customer service hotline at 1-866-985-7877,
9a.m. – 6 p.m. (EST), Monday – Friday, or email us at [email protected].
PROBLEM
Main burner will
not light
Low burner flame
Burner unit

TROUBLESHOOTING

POSSIBLE CAUSE
Gas valve may be off
Fuel tank may be empty
Orifice blocked
Air in supply system
Loose connection
Igniter fails
Gas pressure low with valve
open full
New cylinder or 1st ignition
Natural gas source valve on,
no gas flow
Pressure is low
Gas hose is kinked
Control knob at max
Carbon on reflector &
emitter screen
Thick black smoke
15
CORRECTIVE ACTION
Turn gas valve ON
Refill LPG tank
Clean or replace orifice
Purge air from lines. Open gas
lines and depress control knob
for 2-3 mins.
Check all fittings
Use stick lighter to manually
light
Replace gas source supplier
regulator
Purge air from lines
Replace hose/regulator
assembly
Replace gas source supplier
regulator
Check & straighten or replace
Check for obstruction at
passageways and orifices
Clean components as needed
Blockage in burner
assembly--thoroughly clean
burner