General Information about DUI/DWI
The legal limit for intoxication (DUI/DWI) is 0.08% BAC across most of the USA.
According to the American Medical Association (AMA), a BAC of 0.05% is
enough to impair the ability to drive. You should never operate a motor vehicle
when you are impaired by the consumption of alcohol, drugs or lack of proper
rest.
Warnings
a. Wait at least 20 minutes after eating or drinking before testing. Alcohol
remaining in the mouth, or even excess saliva, may interfere with testing.
This includes alcohol-based mouthwash or similar products.
b. Avoid testing in high wind or enclosed spaces. Poor ventilation may also
lengthen the time required for warm up between tests.
c. Do not blow smoke, saliva or other contaminants into the mouthpiece, as the
sensor may become damaged.
d. Do NOT use the AlcoMate Prestige as a tool to drink and drive.
e. Keep out of extreme temperatures and out of the reach of children.
f.
To maintain accuracy, we recommend replacing the alcohol sensor module
inside the AlcoMate Prestige every 200 tests or at least once a year,
whichever comes first. Large numbers of "high positive" (high alcohol)
readings may require replacing the module much sooner than normally
expected.
g. WARNING DISPLAY "Flo": If you see "Flo" in the display, the breath
sample was not long enough for measurement. Please try again and make
sure the breath is strong and steady during sampling. As soon as you start
blowing into the device, you will hear a long beep indicating how long you
should blow.
h. WARNING DISPLAY "SEn": If you see "SEn" in the display, there is a
general sensor module error. One reason for this error is if the new
replacement sensor module is a different COLOR than the original. You can
ONLY use sensor modules with the proper (matching) color. If this is not the
case, you may return the device for technical service.
i.
WARNING DISPLAY "Bat": If you see "Bat" in the display, the battery power
is low. Please replace the batteries.
Remove the battery cover at the bottom of the unit and
replace the old batteries with two new 1.5V "AA" batteries.
Make sure to properly align the batteries by looking at the +/-
marks.