Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure regulator on the line
before the appliance.
Install a cut-off valve for each supply on the line before the appliance.
Water connections are fitted in the lower part on the right-hand side of the appliance.
Make connections according to regulations currently in force.
Once all the connections have been made, the appliance and the overall installation must be checked
following the directions given in this manual.
Check in particular:
that the protective film has been removed from the external surfaces;
that the lower front panel removed for the electrical connection of the appliance has been fitted back
into position;
that connections have been made in accordance with the requirements and directions indicated in
this manual;
that all safety requirements in current standards, statutory regulations and directives have been met;
that the water connections are leak-free;
that the electrical connection has been performed according to standards.
In addition, check that once the appliance has been installed, the power cord is neither subject to stretch
nor in contact with nor surfaces.
Now proceed to light the appliance as directed in the instructions for use.
While the appliance is in use, voltage should not differ from the nominal voltage more than +/- 10%.
The test report must be completed in full and submitted to the customer who should then sign in
acceptance. With effect from this moment, the appliance is covered by the manufacturer's warranty.
2.3.1. NEW SETTING PARAMETERS WORK'S DIGITAL THERMOSTAT
Keeping pressed at the same time the button "SET" and arrow down "▼" you enter in the following
functions:
-
hy1 = Differential : (-full Sc./full Sc.).The intervention differential for set point. It can be set
with positive or negative value; anyway it's not suggested any change.
-
opb = Probe calibration :( to modify only in the case in which the temperature on the
display is different from that of the product in the basin)
-
pbct = Kind of Probe. ( DO NOT MODIFY ANYWAY THE PARAMETER SET VALUE)
To modify press "SET" and with the arrows "▲▼" change the function type.
In the case of probe "K" fault, on both safety and work's thermostats, on the display appears "pfo" and all
functions are stopped till the probe functions are reset.
Instruction manual for installation, maintenance and use
Electric Kettles PMDE...

2.2.2. CONNECTION TO WATERWORKS

2.3. COMMISSIONING AND TESTING
- GB -