Material Safety Data Sheet (English Only)
SECTION 10 - STABILITY AND REACTIVITY
STABILITY: Stable.
INCOMPATIBILITY WITH OTHER MATERIALS: Strong oxidizers
HAZARDOUS POLYMERIZATION: Will not occur
HAZARDOUS DECOMPOSITION PRODUCTS: During a fire, toxic gases may be generated by thermal
decomposition or combustion. Avoid breathing smoke.
SECTION 11 - TOXICOLOGICAL INFORMATION
This material has been evaluated by Xerox Corporation. The toxicity data noted below is based on test results of
similar toners.
Oral LD50: >5 g/kg (rats), practically non-toxic
Dermal LD50: > 5 g/kg (rabbits), practically non-toxic
Inhalation LC50: > 2 mg/l (rats; 4 hour exposure), practically non-toxic
Eye Irritation: Not an irritant
Skin sensitization: Not a sensitizer
Skin irritation: Not an irritant
Human Patch: Non-irritating, non-sensitizing
Mutagenicity: No mutagenicity detected in Ames assay
Carcinogens: None present
Additional Information: The results obtained from a Xerox sponsored Chronic Toner Inhalation Study
demonstrated no lung changes in rats for the lowest (1 mg/m3) exposure level (ie., the level most relevant to
potential human exposure). A very slight degree of fibrosis was noted in 25% of the animals at the middle (4 mg/
m3) exposure level, while a slight degree of fibrosis was noted in all the animals at the highest (16 mg/m3)
exposure level. The findings are attributed to "lung overloading", a generic response to excessive amounts of any
dust retained in the lungs for a prolonged period. This study was conducted using a special test toner to comply with
EPA testing protocol. The test toner was ten times more respirable than commercially available Xerox toner and
would not be functionally suitable for Xerox equipment.
SECTION 12 - ECOLOGICAL INFORMATION
Aquatic LC50: > 1000 mg/l (fathead minnows); non-toxic
SECTION 13 - DISPOSAL CONSIDERATIONS
This material is not a RCRA hazardous waste as specified in 40 CFR 261. State and local waste disposal
requirements, however, may be more restrictive. Dispose in accordance with all federal, state, and local regulations.
Incinerate only in a closed container.
SECTION 14 - TRANSPORTATION INFORMATION
DOT: Not regulated.
SECTION 15 - REGULATORY INFORMATION
TSCA: All components of these toners have been manufactured in compliance with TSCA.
RCRA: TCLP metals below hazardous waste levels set by EPA.
CANADIAN WHMIS: These toners are not regulated as controlled products under the Workplace Hazardous
Material Information System (WHMIS).
Phaser™ 4400 Laser Printer
21