eControls Comfort365 C365C32 Podręcznik instalatora - Strona 4

Przeglądaj online lub pobierz pdf Podręcznik instalatora dla Termostat eControls Comfort365 C365C32. eControls Comfort365 C365C32 4 stron. Wiring hub, model wh11 and wh32
Również dla eControls Comfort365 C365C32: Podręcznik instalatora (8 strony)

USING WIRELESS UPSTAIRS SENSORS
Before installing the wireless upstairs temperature sensor, the
ELR1 Radio Module needs to be installed in the Wiring Hub.
Installing the eLink Radio Module
!
WARNING
Always turn power off before installing the eLink Radio
Module. Do not turn power on until AFTER the wireless
sensors have been installed and the sensor numbers set,
as shown in the following steps. The Wiring Hub will
automatically detect the Radio and the sensors being used
when powered up.
The ELR1 eLink Radio Module plugs into the two 6-pin
terminal strips on the WH11.
Wiring Hub.
Installing Upstairs Wireless Sensors
The TS5WL is wireless and powered by two
AA batteries. Two upstairs temperature
sensors can be used and the temperatures
are averaged. For a single sensor installation,
install the sensor on an interior wall about 4-
feet above the floor and in a location that best
senses the upstairs temperature.
For a dual sensor installation, install the
sensors in locations that will best sense the
average upstairs temperature. Mount the
TS5WL subbase using the screws provided.
Install two AA batteries as shown.
elink Radio Module.
Setting Wireless Sensors as #1 or #2
The TS5WL is factory set as #1 wireless temperature sensor.
If two upstairs temperature sensors are used, set the address
number on the second sensor to #2. The sensor location
needs to be documented for future reference. Use the
removable labels included with the thermostat to identify the
sensors as #1 or #2. Place the labels on the front of the
thermostat over the battery cover.
Press the push button and the LED will blink once, then twice
and repeat this pattern. To set the sensor as the #1 sensor,
release the push button switch after one blink or after two
blinks to set it as #2 sensor. After releasing the push button,
the LED will blink yellow once to indicate successful
communication or blink red indicating that communication was
not successful.
1 Blink = #1 Sensor
2 Blinks = #2 Sensor
!
After setting the sensor number, power can now be applied
to the Wiring Hub. The Wiring Hub will automatically detect
the Radio and the sensors being used when powered up.
Selecting a Different Home Number
When two or more wireless Comfort365 installations are within
300-feet of each other, the C365 thermostat and upstairs
wireless temperature sensors must be set to different Home
numbers so they do not interfere with one another.
Comfort365 Thermostat
Use Installer Option 25 to set a new Home number.
Upstairs Wireless Temperature Sensors
Remove one of the batteries to remove power to the sensor.
While pressing the push button switch on the sensor, re-install
the battery. The LED will blink red once, then two rapid blinks,
then three rapid blinks and so on. Release the switch after the
number of blinks corresponding to the Home number to be set.
Changing the Home number does not affect the assignment as
the #1 or #2 sensor.
4
Push Button
Switch
LED Indicator