eControls R80DWL Podręcznik użytkownika i instalatora - Strona 5

Przeglądaj online lub pobierz pdf Podręcznik użytkownika i instalatora dla Termostat eControls R80DWL. eControls R80DWL 8 stron. Direct damper control

INSTALLER
!
CAUTIONS
Read and follow all instructions carefully.
Read entire manual before installing products.
Follow all local electrical codes during installation. All
wiring must conform to local and national electrical
codes.
Use cautions when mounting components to surfaces
that may have concealed wiring beneath the surface.
Ensure that the installation process does not alter the
damper in a way that will cause interference to the blade
moving freely.
Caution! Direct Damper Controls are not an
alternative to zoning. Installing too many controls on
a single HVAC system could cause airflow and
pressure problems.
1
1) Remove the Subbase Before Installation
Hold the sub-base with one hand, press the case as shown
below and pull the bottom of the thermostat from the sub-base.
Press here to release
case from sub-base.
1

2) Installing the Subbase

The thermostat can be installed on any interior wall
approximately 5 feet above the floor. To insure accurate
reading of the space temperature, the thermostat should not be
in direct sunlight.
Install the subbase using
two #8 or #6 sheet metal
screws with wall anchors
where required. Level the
thermostat for appearance.
1

3) Installing the Batteries

Slide the battery cover off and
install two AA lithium or alkaline
batteries. Install the batteries
with the positive terminals to
the right as shown. Replace
the battery cover.

INSTALLER OPTIONS

Option
Description
01
Zone number
Range
1 to 8
02
Home Address number
Range
1 to 8
03
Dead-band Differential
Range
1 to 5 F
04
Update interval
Range
5 to 30 minutes
05
LCD back-light control
Range
0- On with key
06
High setpoint limit
Range
60 to 90 F
07
Low setpoint limit
Range
55 to 80 F
08
Damper factor
Range
0- 8%/F 1-16%/F
09
Night airflow
Range
0 to 100%
10
Off airflow
Range
0 to 100%
5
Default
1
1
o
1 F
o
10 minutes
On with key stroke
o
80 F
o
o
65 F
o
0- 8%/F
50%
50%