eControls Comfort365 C365T11 Podręcznik instalatora i użytkownika - Strona 7

Przeglądaj online lub pobierz pdf Podręcznik instalatora i użytkownika dla Tłumiki ognia i dymu eControls Comfort365 C365T11. eControls Comfort365 C365T11 13 stron.
Również dla eControls Comfort365 C365T11: Podręcznik użytkownika (4 strony), Podręcznik instalatora i użytkownika (13 strony), Podręcznik użytkownika (4 strony), Podręcznik instalatora i użytkownika (13 strony), Podręcznik instalatora i użytkownika (13 strony), Instalacja (2 strony)

eControls Comfort365 C365T11 Podręcznik instalatora i użytkownika
03 Setting the Compressor Stages
Factory Default: 1 . Range: 0 or 1
This option is used to set the number of
compressor stages.
Use the UP/DOWN
Option
keys to set 0 or 1
stage.
Touch NEXT or
ENTER.
04 Setting the Heating Stages
Factory Default: 1 Stage. Range: 0, 1 or 2
Use the UP/DOWN
Option
keys to set 0, 1 or 2
stage.
Touch NEXT or
ENTER.
05 Setting the Fan Operation
(Only displayed if Gas/Electric equipment,
GE, is selected in Option 01)
Factory Default: Gas. Range: GA or EL
Use the UP key to
Option
select "EL" for electric
operation where the
thermostat activates
the indoor fan (G
terminal) during
heating calls or DOWN key to select GA for gas
operation where the equipment plenum sensor
activates the indoor fan in heating calls.
Touch NEXT or ENTER.
06 Compressor Minimum Off Time
Factory Default: 2 Min. Range: 0 to 9 Min.
Use the UP/DOWN
Option
keys to change the
minimum off time
(minutes) before
restarting the
compressor.
Touch NEXT or ENTER.
07 Heating Minimum Off Time
Factory Default: 0 Min. Range: 0 to 9 Min.
Use the UP/DOWN
Option
keys to change the
minimum off time
(minutes) before
restarting a gas
furnace or electric
strip heater.
Touch NEXT or ENTER.
INSTALLER SECTION
08 Minimum Run Time
Factory Default: 2 Min. Range: 0 to 9 Min.
Use the UP/DOWN
keys to change the
minimum run time
(minutes) before
turning a system off.
Touch NEXT or ENTER.
NEXT
ENTER
09 Setting On-Off Temp Differential
Factory Default: #1. Range: 0, 1 or 2.
Use the UP/DOWN
keys to select 0, 1,
2.
Touch NEXT or
ENTER.
Differential Mode0
NEXT
ENTER
Differential Mode1
Differential Mode2
10 Smart Recovery
Factory Default: Off. Range: On or Off.
Smart recovery initiates a heating or cooling call
so that the space is at temperature when the
setback period ends.
Use the UP key to
select ON to turn on
smart recovery or
NEXT
ENTER
the DOWN key to
select OF to turn
smart recovery off.
Touch NEXT or ENTER.
11 Vacant Heating Setpoint
Factory Default: 65 F.
Use the UP/DOWN
keys to select the
heating temperature
when the space is
vacant.
NEXT
ENTER
Touch NEXT or ENTER.
12 Vacant Cooling Setpoint
Factory Default: 80 F.
Use the
UP/DOWN
keys to select the
cooling temperature
when the space is
vacant.
NEXT
ENTER
Touch NEXT or ENTER.
Option
NEXT
ENTER
Option
NEXT
ENTER
o
0.5 On/Off Span.
o
1.0 On/Off Span.
o
1.5 On/Off Span.
Option
NEXT
ENTER
o
o
o
Range: 44 F to 75 F
Option
Heat
Vacant
NEXT
ENTER
o
o
o
Range: 74 F to 95 F
Option
Cool
Vacant
NEXT
ENTER
Page 7 of 12
13 Calibrate Living Area Temperature Sensor
Factory Default: None.
Range - +/-5
Use the UP/DOWN
Option
keys to change the
Living area
temperature to the
temperature that the
user feels is correct.
Touch NEXT or ENTER.
14 Calibrate Sleeping Area Temperature Sensor
Factory Default: None.
Range - +/-5
Use the UP/DOWN
Option
keys to change the
Sleeping area
temperature to the
temperature that the
user feels is correct.
Touch NEXT or ENTER.
15 Airflow Update Time
Factory Default: 2 Min. Range: 1 to 20 Min.
This is the frequency, in minutes, that the damper
position is updated.
Use the
UP/DOWN
Option
keys to set the time
in minutes to update
the sleeping and
living area airflow.
Touch NEXT or ENTER.
16 Night Level LCD Backlight
Factory Default: On. Range: On or Off.
The LCD has a low
level backlight that
can be used as a
Night
night light.
Use the
UP
key to
turn the low level
backlight ON or touch the
DOWN
OFF.
Touch NEXT or ENTER.
17 Airflow Control, On or Off
Factory Default: On. Range: On or Off.
This option turns the automatic airflow control on
or off. If off, the dampers fully open, nighttime
airflow options are disabled and airflow is no
longer displayed on the thermostat.
Use the
UP
key to
Sleeping
select ON for airflow
Airflow %
control or touch the
Living
DOWN
key to select
OFF to disable
airflow control.
Touch NEXT or ENTER.
If Airflow Control was off and is now being turned on,
the Nighttime Airflow option can be turned on using the
User Options.
o
Living
NEXT
ENTER
o
Sleeping
NEXT
ENTER
NEXT
ENTER
Option
NEXT
ENTER
key to turn
Option
NEXT
ENTER