Yamaha Silent Cello SVC110 Instrukcja serwisowa - Strona 14

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Instrument muzyczny Yamaha Silent Cello SVC110. Yamaha Silent Cello SVC110 29 stron. Yamaha silent electric cello owner's manual
Również dla Yamaha Silent Cello SVC110: Instrukcja obsługi (12 strony), Instrukcja obsługi (13 strony)

Yamaha Silent Cello SVC110 Instrukcja serwisowa
SVC110/SVC110S
I
INSPECTIONS
1.
Preparations
1-1
Unit Setting
Unless otherwise specified, the controls and switches are to be set as follows.
AUX VR
VOLUME
POWER switch
REVERB switch
The [PHONES] and [LINE OUT] terminals are to be terminated with the following resistors.
PHONES
LINE OUT
1-2
Measuring instruments and jigs
The following measuring instruments and jigs are used for inspection.
Measuring instruments : low-freqency oscillator, level meter.
Jigs
2.
Inspections
Items
Output level 1
PHONES (L)
PHONES L
PHONES (R)
Output level 2
PHONES (L)
PHONES R
PHONES (R)
Output level 3
LINE OUT (L)
LINE OUT L
LINE OUT (R)
Output level 4
LINE OUT (L)
LINE OUT R
LINE OUT (R)
Output level 5
PHONES (L/R) : -21.5 ±2 dBu
PICKUP INPUT
(1 kHz)
Output level 6
PHONES (L/R) : -18.5 ±2 dBu
PICKUP INPUT
(12 kHz)
Output level 7
PHONES (L/R) : -17.5 ±2 dBu
PICKUP INPUT
(120 Hz)
Output level 8
PHONES (L/R) : -24 ±4 dBu
PICKUP INPUT
(60 Hz)
Noise level
PHONES (L/R) : Less than -60 dBu
PHONES (L/R)
Noise level
LINE OUT (L/R) : Less than -60 dBu
LINE OUT (L/R)
Noise level
LINE OUT (L/R) : Less than -60 dBu
LINE OUT (L/R)
* Check by the sense of hearing.
RM (ROOM) : Reverberation time 1.5 sec.
REVERB MODE
HL 1 (HALL1) : Reverberation time 1.5 sec.
HL 2 (HALL2) : Reverberation time 2.0 sec.
14
: Maximum
: Maximum
: ON (REV OFF mode)
: RM
: 150 ohms
: 10 k-ohms
* Use a flat filter when measuring the noise level.
: AC adaptor (PA-3C), powered speaker, stereo sound source (such as a CD player), headphones.
Specification
: -5 ±2 dBu
: Less than -60 dBu
: -60 dBu or less
: -5 ±2 dBu
: -4.5 ±2 dBu
: Less than -60 dBu
: Less than -60 dBu
: -4.5 ±2 dBu
Applied signal and settings
AUX IN L : -20 dBu/1 kHz, sine wave
AUX IN R : -20 dBu/1 kHz, sine wave
AUX IN L : -20 dBu/1 kHz, sine wave
AUX IN R : -20 dBu/1 kHz, sine wave
Apply a 1 kHz -30 dBu sine wave signal
to the CN1 1st pin of the MA circuit board.
Apply a 12 kHz -30 dBu sine wave signal
to the CN1 1st pin of the MA circuit board.
Apply a 120 Hz -30 dBu sine wave signal
to the CN1 1st pin of the MA circuit board.
Apply a 60 Hz -20 dBu sine wave signal
to the CN1 1st pin of the MA circuit board.
Apply ground to the CN1 1st pin of the MA
circuit board.
(Connect pin 1 and pin 2.)
Play the strings using the fingers, then stop
the vibration of the strings and check the
reverberations.
[
0 dBu=0.775 Vrms
Set the unit as specified in 1-1
POWER SW : ON (Reverb off)
REVERB SW: RM
POWER SW : REV.ON
REVERB SW: RM
Set the unit as specified in 1-1
and the [POWER] switch to the
[REV.ON] position; set the
[REVERB] switch to the appropriate
position.
]