DirectConnect 19931 Podręcznik użytkownika - Strona 4
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Stojaki i stojaki DirectConnect 19931. DirectConnect 19931 4 stron. Professional series racks complete rack with casters, power strip, thermal control and dual fans
Step 3: Unpacking Carton 3 of 3
Installing the Top with dual fans and Base Assemblies, Casters, Legs,
and Base Cable Plates
(as needed)
Fig.4
Fig. 5a
Base Cable Plates (E) to the Rack Assemblies
Installing the four (4)
(as needed)
: Do to the height and weights of the Professional Series Racks do not move and/or stand up by yourself
C
AUTION
assistance is required. Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
Stand up the completed rack assemblies. Using two
each of the
Base Cable Plates
(as needed)
side of Base Assembly
as shown in Figure 5a.
(5)
Fig.5b
Step 4: Attaching the doors and panels to the
Rack Assemblies
Attach the Custom Tempered Glass Door
Back Door
, and the left & right Side Panels
(2)
completed rack assemblies as shown in Figure 6.
Installing & Adjusting the Front (1) & Back (2) Doors.
1) The Front Door (1) and the Back Door (2) are removable at
any time. Just pull down on the top tap while holding the door.
The top of the door will then fall out of place, then pull up on
the bottom tab and lift the door out of the frame.
2) There may be times when the door may need to open to the
other directions. The door's opening direction can be changed.
Remove the door and turn it so that the handle is on the other
side. Insert the tabs into the holes and close the door.
and assemble Top & Base Assembly to rack.
to rack assembly.
Using six
M5x10 screws (F) attach
(6)
the Top Assembly with dual fans (4) as
unpacked from carton 1 of 3 and attach
to Rack Assembly as shown in Figure 4.
Using four
M5x10 screws (F) attach
(4)
the Base Assembly (5) as unpacked
from carton 1 of 3 and attach to Rack
Assembly as shown in Figure 4.
Using six
M5x10 screws (F)
(6)
attach two
Locking Casters (D)
caster)
(2)
onto the bottom Front Assembly (1)
and two
Standard Casters (D) onto
(2)
the bottom Back Assembly (2) as
shown in Figure 5a.
Using a wrench attach two
Adjustable Locking Feet (C) onto the
bottom Front Assembly (1) the
bottom Back Assembly (2) as shown
in Figure 5a.
M5x10 screws
(2)
(Fig.5b) attach each to the top
(E)
, the Vented
(1)
to the
(3)
Fig.6
.
6 / 8
1.0 H
ARDWARE
Actual parts appearance and quantity may differ from illustration.
(six per
of the
(2)
for
ID
Quantity
(F)
1
1
2
1
3
2
4
1
5
1
6
1
7
1
1U Thermal Control
8
1
Power Cord
9
4
10
1
L
:
IST
Description
ID
Quantity
Front Assembly
A
1
Back Assembly
B
1
Side Assembly
C
4
Fan Top Assembly
D
4
Base Assembly
E
4
1U Power Strip
F
42
G
42
H
38
(Thermal)
Keys
I
38
Manual
J
1
K
1
3 / 8
Description
Left Threaded Mounting Rail
Right Threaded Mounting Rail
Adjustable Locking Feet
Heavy Duty Casters
(2- standard / 2 - locking)
Base Cable Plates
M5x10mm bolt
(assembly)
M6x12mm bolt
(assembly)
10-32 bolt
(mounting rails)
10-32 nut
(mounting rails)
Left Knockout Mounting Rail
Right Knockout Mounting Rail