Controls and Functions

Front Panel

q POWER switch and indicator
Turns power to the unit on or off. The indicator lights green
when the power is on.
w PROTECT indicator
When the protection system is active, the indicator lights
red. When this is lit, the amplifier or power supply is auto-
matically shut down, and no sound will be output from the
speakers.
e CLIP indicator
This indicator will light red when the output power exceeds
100 W for an 8Ω load or 200 W for a 4Ω load. When this is
lit, the limiter will automatically operate.
r SIGNAL indicator
This indicator will light green when the output level exceeds
2 Vrms. (This will light at 0.5 W or greater for an 8Ω load,
1W or greater for a 4Ω load.)
t Attenuator
These are detented knobs that attenuate the input signal of
each channel (A–H) over 41 steps in a range of 0 dB – –∞
dB.
• To operate these knobs, use a slotted screwdriver with
NOTE
a blade no wider than 5.5 mm.
Security cover
y MUTE indicator
This will light red when mute is activated.
u MUTE switch
This turns muting on/off for each channel. Use a thin rod to
turn muting on/off.
i PARALLEL indicator
This will light orange when the rear panel MODE switch is
set to PARALLEL.
o BRIDGE indicator
This will light orange when the rear panel MODE switch is
set to BRIDGE.
!0 Screw holes for security cover
If desired, you can use these two screw holes for attaching
the included security cover to prevent the attenuator setting
from being changed. Use the included Allen wrench and
screws to attach the cover.
!1 Air intakes
The amplifier uses forced-air cooling. The variable speed
cooling fan draws air in from the front and exhausts it
through the rear. The cooling fan operates at low speed when
the heat sink temperature is below 65 °C (149 °F), or at high
speed when the temperature exceeds 65 °C (140 °F). Please
be sure that you do not block the air intakes or exhaust vents.
7